Partitioned Raft KV
Warning
Partitioned Raft KV is an experimental feature. It is not recommended that you use it in the production environment. This feature might be changed or removed without prior notice. If you find a bug, you can report an issue on GitHub.
Before v6.6.0, TiKV’s Raft-based storage engine used a single RocksDB instance to store the data of all Regions of the TiKV instance.
To support larger clusters more stably, starting from TiDB v6.6.0, a new TiKV storage engine is introduced, which uses multiple RocksDB instances to store TiKV Region data, and the data of each Region is independently stored in a separate RocksDB instance.
The new engine can better control the number and level of files in each RocksDB instance, achieve physical isolation of data operations between Regions, and support stably managing more data. You can see it as TiKV managing multiple RocksDB instances through partitioning, which is why the feature is named Partitioned Raft KV.
Application scenarios
You can use this feature if your TiKV cluster has the following characteristics:
- A single TiKV instance needs to support more data.
- There are many write requests.
- Scale-in and scale-out operations are frequent.
- The workload has a serious read and write amplification.
- TiKV has sufficient memory.
Advantages of this feature are better write performance, faster scaling speed, and larger volume of data supported with the same hardware. It can also support larger cluster scale.
Usage
To enable Partitioned Raft KV, set the configuration item storage.engine to "partitioned-raft-kv"
when creating a cluster. At the same time, you can use the configuration items rocksdb.write-buffer-flush-oldest-first and rocksdb.write-buffer-limit to control the memory usage of RocksDB when using Raft KV.
Restrictions
Partitioned Raft KV has the following restrictions:
- It does not support EBS volume snapshot backup yet.
- It does not support online unsafe recovery or Titan yet.
- It does not support the following subcommands of the tikv-ctl command-line tool:
unsafe-recover
raw-scan
remove-fail-stores
recreate-region
reset-to-version
- It is not compatible with TiFlash yet.
- You cannot enable or disable this feature after the cluster is initialized.