CALIBRATE RESOURCE
The CALIBRATE RESOURCE
statement is used to estimate and output the ‘Request Unit (RU)` capacity of the current cluster.
Note
This feature is only applicable to TiDB Self-Hosted and not available on TiDB Cloud.
Synopsis
CalibrateResourceStmt
WorkloadOption
CalibrateResourceStmt ::= 'CALIBRATE' 'RESOURCE' WorkloadOption
WorkloadOption ::=
( 'WORKLOAD' ('TPCC' | 'OLTP_READ_WRITE' | 'OLTP_READ_ONLY' | 'OLTP_WRITE_ONLY') )
| ( 'START_TIME' 'TIMESTAMP' ('DURATION' stringLit | 'END_TIME' 'TIMESTAMP')?)?
Privileges
To execute this command, make sure that the following requirements are met:
- You have enabled tidb_enable_resource_control.
- The user has
SUPER
orRESOURCE_GROUP_ADMIN
privilege. - The user has the
SELECT
privilege for all tables in theMETRICS_SCHEMA
schema.
Methods for estimating capacity
TiDB provides two methods for estimation:
Estimate capacity based on actual workload
If your application is already running in a production environment, or you can run actual business tests, it is recommended to use the actual workload over a period of time to estimate the total capacity. To improve the accuracy of the estimation, observe the following constraints:
- Use the
START_TIME
parameter to specify the time point at which the estimation starts, in the format of2006-01-02 15:04:05
. The default estimation end time is the current time. - After specifying the
START_TIME
parameter, you can use theEND_TIME
parameter to specify the estimation end time, or use theDURATION
parameter to specify the estimation time window fromSTART_TIME
. - The time window ranges from 10 minutes to 24 hours.
- In the specified time window, if the CPU utilization of TiDB and TiKV is too low, you cannot estimate the capacity.
Note
TiKV does not monitor CPU usage metrics on macOS. It does not support capacity estimation based on the actual workload on macOS.
Estimate capacity based on hardware deployment
This method mainly estimates capacity based on the current cluster configuration, combined with the empirical values observed for different workloads. Because different types of workloads require different ratios of hardware, the output capacity of the same configuration of hardware might be different. The WORKLOAD
parameter here accepts the following different workload types. The default value is TPCC
.
TPCC
: applies to workloads with heavy data write. It is estimated based on a workload model similar toTPC-C
.OLTP_WRITE_ONLY
: applies to workloads with heavy data write. It is estimated based on a workload model similar tosysbench oltp_write_only
.OLTP_READ_WRITE
: applies to workloads with even data read and write. It is estimated based on a workload model similar tosysbench oltp_read_write
.OLTP_READ_ONLY
: applies to workloads with heavy data read. It is estimated based on a workload model similar tosysbench oltp_read_only
.TPCH_10
: applies to AP queries. It is estimated based on 22 queries fromTPCH-10G
.
Note
The RU capacity of a cluster varies with the topology of the cluster and the hardware and software configuration of each component. The actual RU that each cluster can provide is also related to the actual workload. The estimated value based on hardware deployment is for reference only and might differ from the actual maximum value. It is recommended to estimate capacity based on actual workload.
Examples
Specify the start time START_TIME
and the time window DURATION
to view the RU capacity according to the actual workload.
CALIBRATE RESOURCE START_TIME '2023-04-18 08:00:00' DURATION '20m';
+-------+
| QUOTA |
+-------+
| 27969 |
+-------+
1 row in set (0.01 sec)
Specify the start time START_TIME
and the end time END_TIME
to view the RU capacity according to the actual workload.
CALIBRATE RESOURCE START_TIME '2023-04-18 08:00:00' END_TIME '2023-04-18 08:20:00';
+-------+
| QUOTA |
+-------+
| 27969 |
+-------+
1 row in set (0.01 sec)
When the time window range DURATION
does not fall between 10 minutes and 24 hours, an error occurs.
CALIBRATE RESOURCE START_TIME '2023-04-18 08:00:00' DURATION '25h';
ERROR 1105 (HY000): the duration of calibration is too long, which could lead to inaccurate output. Please make the duration between 10m0s and 24h0m0s
CALIBRATE RESOURCE START_TIME '2023-04-18 08:00:00' DURATION '9m';
ERROR 1105 (HY000): the duration of calibration is too short, which could lead to inaccurate output. Please make the duration between 10m0s and 24h0m0s
The monitoring metrics for the capacity estimation based on the actual workload feature include tikv_cpu_quota
, tidb_server_maxprocs
, resource_manager_resource_unit
, process_cpu_usage
, tiflash_cpu_quota
, tiflash_resource_manager_resource_unit
, and tiflash_process_cpu_usage
. If the CPU quota monitoring data is empty, there will be an error with the corresponding monitoring metric name, as shown in the following example:
CALIBRATE RESOURCE START_TIME '2023-04-18 08:00:00' DURATION '60m';
Error 1105 (HY000): There is no CPU quota metrics, metrics 'tikv_cpu_quota' is empty
If the workload in the time window is too low, or the resource_manager_resource_unit
and process_cpu_usage
monitoring data is missing, the following error will be reported. In addition, because TiKV does not monitor CPU utilization on macOS, it does not support capacity estimation based on the actual workload, and will also report this error.
CALIBRATE RESOURCE START_TIME '2023-04-18 08:00:00' DURATION '60m';
ERROR 1105 (HY000): The workload in selected time window is too low, with which TiDB is unable to reach a capacity estimation; please select another time window with higher workload, or calibrate resource by hardware instead
Specify WORKLOAD
to view the RU capacity. The default value is TPCC
.
CALIBRATE RESOURCE;
+-------+
| QUOTA |
+-------+
| 190470 |
+-------+
1 row in set (0.01 sec)
CALIBRATE RESOURCE WORKLOAD OLTP_WRITE_ONLY;
+-------+
| QUOTA |
+-------+
| 27444 |
+-------+
1 row in set (0.01 sec)