Plugin List
View All Available Plugins
The plugin management page displays all the pluggable modules available and detailed information, including the name of the plug-in, associated node type, plug-in category, driver library name and description, as shown in the following figure.
Click the Document
button in the upper right corner of the plugin card to jump to the documentation for the specific use and description of the driver.
The plug-in types include the following 3 modes:
- Static: cannot be deleted
- System: cannot be deleted, native
- Custom: Deletable, user-developed or custom-developed
TIP
Users can filter out the plugins for northbound applications or southbound devices from the dropdown box.
Add a New Pluggable Module
Click on the Add Plugin
button in the upper right corner as shown below
To add a new Pluggable module,
- Fill in the path and file name of the .so file that needs to be added.
- Click on the
Create
button to move .so file to the build directory.
TIP
Please make sure that the plugin .so file you have written is placed under the neuron/build/plugins directory before adding it. For specific plugin development tutorials, please refer to SDK Tutorial.
Southbound Plugin Modules
Global Standards
Protocol Name | Interface | Type | Available | Remark |
---|---|---|---|---|
Modbus TCP | Ethernet | Open Source | Yes | |
Modbus RTU | Serial | Open Source | Yes | |
Modbus RTU over TCP | Ethernet | Open Source | Yes | |
OPC UA | Ethernet | Commercial | Yes | |
CIP Ethernet/IP | Ethernet | Commercial | Yes | CIP – Common Industrial Protocol |
PLC Drivers
Protocol Name | Interface | Type | Available | Remark |
---|---|---|---|---|
Siemens 3964R/RK512 | Serial | Commercial | V1.x only | For S5 and S7 |
Siemens Industrial Ethernet ISO for S7-200/300/400/1200/1500 | Ethernet | Commercial | Yes | |
Siemens Fetch Write for S7-300/400 and CP443 module | Ethernet | Commercial | Yes | |
Allen-Bradley DF1 half-duplex | Serial | Commercial | Yes | For PLC2 and PLC5 |
Allen-Bradley CIP EtherNet/IP | Ethernet | Commercial | Yes | CIP – Common Industrial Protocol |
Schneider PLC Modbus RTU | Serial | Commercial | V1.x only | |
Schneider PLC Modbus TCP | Ethernet | Commercial | V1.x only | |
Schneider Telemecanique UNI-TE | Serial | Commercial | V1.x only | |
ABB SattControl Comli | Serial | Commercial | Yes | |
Omron Host Link | Serial | Commercial | V1.x only | For Single and Multiple connection |
Omron FINS on Host Link | Serial | Commercial | V1.x only | |
Omron FINS on TCP | Ethernet | Commercial | Yes | |
Omron FINS on UDP | Ethernet | Commercial | Yes | |
Mitsubishi MC Protocol for Q series and C24 module | Serial | Commercial | V1.x only | |
Mitsubishi MC Protocol for Q series and E71 module | Ethernet | Commercial | Yes | 3E frame |
Mitsubishi FX Series | Serial | Commercial | V1.x only | |
Mitsubishi FX3U-ENET-ADP | Ethernet | Commercial | Yes | 1E frame |
Mitsubishi 232ADP/485BD: Serial/RS485 | Serial | Commercial | No | |
Panasonic FP series MEWTOCOL-COM | Serial | Commercial | No | |
Panasonic FP series MEWTOCOL-COM | Ethernet | Commercial | Yes | |
Panasonic FP series MEWTOCOL-DAT | Ethernet | Commercial | No | |
Beckhoff ADS/AMS TCPIP | Ethernet | Commercial | Yes | |
Keyence CIP Ethernet/IP | Ethernet | Commercial | Yes | CIP – Common Industrial Protocol |
Keyence MC Protocol | Ethernet | Commercial | Yes | Mitsubishi MC Protocol |
Delta DVP communication protocol | Serial | Commercial | No | |
Delta Modbus TCP | Ethernet | Commercial | Yes | |
Delta CIP Ethernet/IP | Ethernet | Commercial | Yes | CIP – Common Industrial Protocol |
Fatek FACON serial | Serial | Commercial | No | |
Fatek FACON ethernet | Ethernet | Commercial | No | |
GE FANUC 90-30 SNPX | Serial | Commercial | No | |
GE FANUC 90-30 Ethernet SRTP | Ethernet | Commercial | No |
Electricity
Protocol Name | Interface | Type | Available | Remark |
---|---|---|---|---|
DL/T645-1997 | Serial | Commercial | Yes | Chinese standards for power meters |
DL/T645-2007 | Serial | Commercial | Yes | Chinese standards for power meters |
IEC 60870-5-101 | Serial | Commercial | No | |
IEC 60870-5-102 | Serial | Commercial | No | |
IEC 60870-5-103 | Serial | Commercial | No | |
IEC 60870-5-104 | Ethernet | Commercial | Yes | |
IEC 61850 | Ethernet | Commercial | Yes | |
DNP3 | Ethernet | Commercial | No |
Building Automation
Protocol Name | Interface | Type | Available | Remark |
---|---|---|---|---|
KNXnet IP | Ethernet | Commercial | Yes | |
BACnet IP | Ethernet | Commercial | Yes | |
BACnet MS/TP | Serial | Commercial | No | |
LON | Ethernet | Commercial | No |
CNC Machines & Robotics
Protocol Name | Interface | Type | Available | Remark |
---|---|---|---|---|
MTConnect | Ethernet | Commercial | No | |
Fanuc 0i, 30i, 31i, 32i and 35i | Ethernet | Commercial | Yes | |
Mitsubishi M800/M80 | Ethernet | Commercial | No | |
Siemens 840D、810、828D | Ethernet | Commercial | No |
Northbound Plugin Modules
Cloud Connectivity
Protocol Name | Type | Available | Remark |
---|---|---|---|
RESTful API | Open Source | Yes | |
MQTT | Open Source | Yes | |
MQTT Sparkplug B | Commercial | Yes | |
Websocket | Commercial | Yes |
Application
Protocol Name | Type | Available | Remark |
---|---|---|---|
eKuiper Stream Processing | Open Source | Yes |
EMQ License Policy for Commercial Modules
Core framework, dashboard, and a few plugin modules such as Modbus TCP, MQT, and eKuiper are open source under LGPLv3 license. Neuron may run with these open-source modules without an EMQ license. But all other commercial plugin modules require an official EMQ license to run without limitation.
30 Connections forever free
For these commercial modules, Neuron also provides a forever free quota (with 30 connections and 30 data tags) for your exploration.
Note: The Fanuc Focas Ethernet and Mitsubishi CNC plugins are not within the scope of the 30-point free-for-life offer. If you wish to try them out, you can directly contact us.
Apply for License
A trial EMQ license can be downloaded from our official website https://www.emqx.com/en/apply-licenses/neuron. All available modules could be used with a limitation of 100 connections and 1000 data tags for 15 days. If the trial EMQ license is expired, you can re-apply for the trial EMQ license via our official website again. However, a mailbox can only apply for a trial license up to two times.
- Each plugin module can be authorized independently in the EMQ license.