Diagnostics reporting
The YB-Master and YB-TServer nodes report cluster diagnostics to Yugabyte’s diagnostics service every time a new cluster gets created and every hour thereafter. User data stored in YugabyteDB as well as any personally identifiable information regarding the user is never collected or reported.
Data collected
The data collected depends on the collection level set. See Configuration options below on how to change the collection level.
Collection level: low
Collection time
Cluster uuid
Node uuid
Node type (tserver or master)
Number of masters (yb-master processes)
Number of tablet servers (yb-tserver processes)
Number of tables
Number of tablets
Cluster configuration (gflags)
Host name (for each node where yb-master and yb-tserver processes are running)
Username (for each node where yb-master and yb-tserver processes are running)
Collection level: medium [Default]
Everything we collect for level “low” plus:
Performance metrics
RPC metrics
Collection level: high
Same as medium
level. In other words, no extra information is collected for this level. It will be used in the future to collect additional dianostics information such as error logs.
Example of metrics collected
[
{
"type": "tablet",
"id": "eca8b3cfb2ee4eca94dde519634e1e38",
"attributes": {
"partition": "hash_split: [16380, 19110)",
"table_name": "redis",
"table_id": "82f5f7ab81a44923b5f544fbd0664afe"
},
"metrics": [
{
"name": "log_reader_bytes_read",
"value": 0
},
{
"name": "log_reader_entries_read",
"value": 0
},
{
"name": "log_reader_read_batch_latency",
"total_count": 0,
"min": 0,
"mean": 0,
"percentile_75": 0,
"percentile_95": 0,
"percentile_99": 0,
"percentile_99_9": 0,
"percentile_99_99": 0,
"max": 0,
"total_sum": 0
}
]
}
}
Example of RPCs being collected
{
"inbound_connections": [
{
"remote_ip": "10.150.0.20:41134",
"state": "OPEN",
"remote_user_credentials": "{real_user=yugabyte, eff_user=}",
"processed_call_count": 2456
},
{
"remote_ip": "10.150.0.20:54141",
"state": "OPEN",
"remote_user_credentials": "{real_user=yugabyte, eff_user=}",
"processed_call_count": 2471
}
]
}
Configuration options
You can add the following configuration options, or flags, while starting the YB-Mster and YB-TServer nodes to configure the diagnostics reporting behavior of YugabyteDB.
Flag | Default | Description |
---|---|---|
—callhome_collection_level | medium | Collection level with possible values of low , medium , or high |
—callhome_interval_secs | 3600 | Collection interval in seconds |
—callhome_url | http://diagnostics.yugabyte.com | Endpoint where diagnostics information is reported |
—callhome_enabled | true | Controls whether diagnostics information is collected and reported. Set to false to disable collection. |