NON A11
Module Description
The non a11 plugin is used for NON-A11 device.
Parameter Configuration
Parameter | Description |
---|---|
connection mode | The way the driver connects to the device, the default is client, which means that the neuron driver is used as the client |
host | When neuron is used as a client, host means the ip of the remote device. When used as a server, it means the ip used by neuron locally, and 0.0.0.0 can be filled in by default |
port | When neuron is used as client, port means the tcp port of the remote device. When used as a server, it means the tcp port used by neuron locally. |
site | NON-A11 device site number. |
Support Data Type
- INT16
- UINT16
- INT32
- UINT32
- FLOAT
- STRING
Usage of Address Format
Address Format
COMMAND ! OFFSET[.LEN]
Address Examples
Address | Data Type | Description |
---|---|---|
1!10.20 | string | command 1, offset 10, string length 20 |
12!1 | uint16/int16 | command 12, offset 1 |
20!32 | uint32/int32/float | command 20, offset 32 |