Debezium connector for MySQL

How the connector works

An overview of the MySQL topologies that the connector supports is useful for planning your application. To optimally configure and run a Debezium MySQL connector, it is helpful to understand how the connector tracks the structure of tables, exposes schema changes, performs snapshots, and determines Kafka topic names.

The Debezium MySQL connector has been tested and officially supports MariaDB 11.1.2+. For information about how to connect Debezium to MariaDB, see Using the connector with a MariaDB database.

Supported MySQL topologies

The Debezium MySQL connector supports the following MySQL topologies:

Standalone

When a single MySQL server is used, the server must have the binlog enabled (and optionally GTIDs enabled) so the Debezium MySQL connector can monitor the server. This is often acceptable, since the binary log can also be used as an incremental backup. In this case, the MySQL connector always connects to and follows this standalone MySQL server instance.

Primary and replica

The Debezium MySQL connector can follow one of the primary servers or one of the replicas (if that replica has its binlog enabled), but the connector sees changes in only the cluster that is visible to that server. Generally, this is not a problem except for the multi-primary topologies.

The connector records its position in the server’s binlog, which is different on each server in the cluster. Therefore, the connector must follow just one MySQL server instance. If that server fails, that server must be restarted or recovered before the connector can continue.

High available clusters

A variety of high availability solutions exist for MySQL, and they make it significantly easier to tolerate and almost immediately recover from problems and failures. Most HA MySQL clusters use GTIDs so that replicas are able to keep track of all changes on any of the primary servers.

Multi-primary

Network Database (NDB) cluster replication uses one or more MySQL replica nodes that each replicate from multiple primary servers. This is a powerful way to aggregate the replication of multiple MySQL clusters. This topology requires the use of GTIDs.

A Debezium MySQL connector can use these multi-primary MySQL replicas as sources, and can fail over to different multi-primary MySQL replicas as long as the new replica is caught up to the old replica. That is, the new replica has all transactions that were seen on the first replica. This works even if the connector is using only a subset of databases and/or tables, as the connector can be configured to include or exclude specific GTID sources when attempting to reconnect to a new multi-primary MySQL replica and find the correct position in the binlog.

Hosted

There is support for the Debezium MySQL connector to use hosted options such as Amazon RDS and Amazon Aurora.

Because these hosted options do not allow a global read lock, table-level locks are used to create the consistent snapshot.

Using the connector with a MariaDB database

Although it is possible to use the MySQL driver to connect and stream changes from MariaDB, it’s best to configure the Debezium MySQL connector to use the MariaDB adapter mode, so that the connector can take advantage of the MariaDB driver, and its unique feature stack. To toggle the MariaDB support mode, the connector.adapter configuration property must be specified with a value of mariadb. This mode utilizes the MariaDB driver instead of the MySQL driver, meaning that you must also provide the database protocol and JDBC driver strings that are compliant with MariaDB, see the example below.

MariaDB supplemental configuration

  1. {
  2. ...
  3. "connector.adapter": "mariadb",
  4. "database.protocol": "jdbc:mariadb",
  5. "database.jdbc.driver": "org.mariadb.jdbc.Driver"
  6. }

When the new Debezium MariaDB connector is available in a future release, these supplemental configurations will no longer be necessary. As the connector currently includes both the MySQL and MariaDB drivers, the MariaDB mode is opt-in until Debezium introduces the new MariaDB-specific connector.

After you apply the Maria DB supplemental configuration, the Debezium MySQL connector uses the MariaDB adapter connector, which natively streams changes from MariaDB binary transaction logs. You can use all other MySQL connector properties in conjunction with the preceding supplemental configuration.

Schema history topic

When a database client queries a database, the client uses the database’s current schema. However, the database schema can be changed at any time, which means that the connector must be able to identify what the schema was at the time each insert, update, or delete operation was recorded. Also, a connector cannot necessarily apply the current schema to every event. If an event is relatively old, it’s possible that it was recorded before the current schema was applied.

To ensure correct processing of events that occur after a schema change, MySQL includes in the transaction log not only the row-level changes that affect the data, but also the DDL statements that are applied to the database. As the connector encounters these DDL statements in the binlog, it parses them and updates an in-memory representation of each table’s schema. The connector uses this schema representation to identify the structure of the tables at the time of each insert, update, or delete operation and to produce the appropriate change event. In a separate database schema history Kafka topic, the connector records all DDL statements along with the position in the binlog where each DDL statement appeared.

When the connector restarts after either a crash or a graceful stop, it starts reading the binlog from a specific position, that is, from a specific point in time. The connector rebuilds the table structures that existed at this point in time by reading the database schema history Kafka topic and parsing all DDL statements up to the point in the binlog where the connector is starting.

This database schema history topic is for internal connector use only. Optionally, the connector can also emit schema change events to a different topic that is intended for consumer applications.

When the MySQL connector captures changes in a table to which a schema change tool such as gh-ost or pt-online-schema-change is applied, there are helper tables created during the migration process. You must configure the connector to capture changes that occur in these helper tables. If consumers do not need the records the the connector generates for helper tables, configure a single message transform (SMT) to remove these records from the messages that the connector emits.

Additional resources

Schema change topic

You can configure a Debezium MySQL connector to produce schema change events that describe schema changes that are applied to tables in the database. The connector writes schema change events to a Kafka topic named _<topicPrefix>_, where _topicPrefix_ is the namespace specified in the topic.prefix connector configuration property. Messages that the connector sends to the schema change topic contain a payload, and, optionally, also contain the schema of the change event message.

The schema for the schema change event has the following elements:

name

The name of the schema change event message.

type

The type of the change event message.

version

The version of the schema. The version is an integer that is incremented each time the schema is changed.

fields

The fields that are included in the change event message.

Example: Schema of the MySQL connector schema change topic

The following example shows a typical schema in JSON format.

  1. {
  2. "schema": {
  3. "type": "struct",
  4. "fields": [
  5. {
  6. "type": "string",
  7. "optional": false,
  8. "field": "databaseName"
  9. }
  10. ],
  11. "optional": false,
  12. "name": "io.debezium.connector.mysql.SchemaChangeKey",
  13. "version": 1
  14. },
  15. "payload": {
  16. "databaseName": "inventory"
  17. }
  18. }

The payload of a schema change event message includes the following elements:

ddl

Provides the SQL CREATE, ALTER, or DROP statement that results in the schema change.

databaseName

The name of the database to which the DDL statements are applied. The value of databaseName serves as the message key.

pos

The position in the binlog where the statements appear.

tableChanges

A structured representation of the entire table schema after the schema change. The tableChanges field contains an array that includes entries for each column of the table. Because the structured representation presents data in JSON or Avro format, consumers can easily read messages without first processing them through a DDL parser.

For a table that is in capture mode, the connector not only stores the history of schema changes in the schema change topic, but also in an internal database schema history topic. The internal database schema history topic is for connector use only and it is not intended for direct use by consuming applications. Ensure that applications that require notifications about schema changes consume that information only from the schema change topic.

Never partition the database schema history topic. For the database schema history topic to function correctly, it must maintain a consistent, global order of the event records that the connector emits to it.

To ensure that the topic is not split among partitions, set the partition count for the topic by using one of the following methods:

  • If you create the database schema history topic manually, specify a partition count of 1.

  • If you use the Apache Kafka broker to create the database schema history topic automatically, the topic is created, set the value of the Kafka num.partitions configuration option to 1.

The format of the messages that a connector emits to its schema change topic is in an incubating state and is subject to change without notice.

Example: Message emitted to the MySQL connector schema change topic

The following example shows a typical schema change message in JSON format. The message contains a logical representation of the table schema.

  1. {
  2. "schema": { },
  3. "payload": {
  4. "source": { (1)
  5. "version": "2.5.4.Final",
  6. "connector": "mysql",
  7. "name": "mysql",
  8. "ts_ms": 1651535750218, (2)
  9. "snapshot": "false",
  10. "db": "inventory",
  11. "sequence": null,
  12. "table": "customers",
  13. "server_id": 223344,
  14. "gtid": null,
  15. "file": "mysql-bin.000003",
  16. "pos": 570,
  17. "row": 0,
  18. "thread": null,
  19. "query": null
  20. },
  21. "databaseName": "inventory", (3)
  22. "schemaName": null,
  23. "ddl": "ALTER TABLE customers ADD middle_name varchar(255) AFTER first_name", (4)
  24. "tableChanges": [ (5)
  25. {
  26. "type": "ALTER", (6)
  27. "id": "\"inventory\".\"customers\"", (7)
  28. "table": { (8)
  29. "defaultCharsetName": "utf8mb4",
  30. "primaryKeyColumnNames": [ (9)
  31. "id"
  32. ],
  33. "columns": [ (10)
  34. {
  35. "name": "id",
  36. "jdbcType": 4,
  37. "nativeType": null,
  38. "typeName": "INT",
  39. "typeExpression": "INT",
  40. "charsetName": null,
  41. "length": null,
  42. "scale": null,
  43. "position": 1,
  44. "optional": false,
  45. "autoIncremented": true,
  46. "generated": true
  47. },
  48. {
  49. "name": "first_name",
  50. "jdbcType": 12,
  51. "nativeType": null,
  52. "typeName": "VARCHAR",
  53. "typeExpression": "VARCHAR",
  54. "charsetName": "utf8mb4",
  55. "length": 255,
  56. "scale": null,
  57. "position": 2,
  58. "optional": false,
  59. "autoIncremented": false,
  60. "generated": false
  61. },
  62. {
  63. "name": "middle_name",
  64. "jdbcType": 12,
  65. "nativeType": null,
  66. "typeName": "VARCHAR",
  67. "typeExpression": "VARCHAR",
  68. "charsetName": "utf8mb4",
  69. "length": 255,
  70. "scale": null,
  71. "position": 3,
  72. "optional": true,
  73. "autoIncremented": false,
  74. "generated": false
  75. },
  76. {
  77. "name": "last_name",
  78. "jdbcType": 12,
  79. "nativeType": null,
  80. "typeName": "VARCHAR",
  81. "typeExpression": "VARCHAR",
  82. "charsetName": "utf8mb4",
  83. "length": 255,
  84. "scale": null,
  85. "position": 4,
  86. "optional": false,
  87. "autoIncremented": false,
  88. "generated": false
  89. },
  90. {
  91. "name": "email",
  92. "jdbcType": 12,
  93. "nativeType": null,
  94. "typeName": "VARCHAR",
  95. "typeExpression": "VARCHAR",
  96. "charsetName": "utf8mb4",
  97. "length": 255,
  98. "scale": null,
  99. "position": 5,
  100. "optional": false,
  101. "autoIncremented": false,
  102. "generated": false
  103. }
  104. ],
  105. "attributes": [ (11)
  106. {
  107. "customAttribute": "attributeValue"
  108. }
  109. ]
  110. }
  111. }
  112. ]
  113. }
  114. }
Table 1. Descriptions of fields in messages emitted to the schema change topic
ItemField nameDescription

1

source

The source field is structured exactly as standard data change events that the connector writes to table-specific topics. This field is useful to correlate events on different topics.

2

ts_ms

Optional field that displays the time at which the connector processed the event. The time is based on the system clock in the JVM running the Kafka Connect task.

In the source object, ts_ms indicates the time that the change was made in the database. By comparing the value for payload.source.ts_ms with the value for payload.ts_ms, you can determine the lag between the source database update and Debezium.

3

databaseName
schemaName

Identifies the database and the schema that contains the change. The value of the databaseName field is used as the message key for the record.

4

ddl

This field contains the DDL that is responsible for the schema change. The ddl field can contain multiple DDL statements. Each statement applies to the database in the databaseName field. Multiple DDL statements appear in the order in which they were applied to the database.

Clients can submit multiple DDL statements that apply to multiple databases. If MySQL applies them atomically, the connector takes the DDL statements in order, groups them by database, and creates a schema change event for each group. If MySQL applies them individually, the connector creates a separate schema change event for each statement.

5

tableChanges

An array of one or more items that contain the schema changes generated by a DDL command.

6

type

Describes the kind of change. The value is one of the following:

    CREATE

    Table created.

    ALTER

    Table modified.

    DROP

    Table deleted.

7

id

Full identifier of the table that was created, altered, or dropped. In the case of a table rename, this identifier is a concatenation of <old>,<new> table names.

8

table

Represents table metadata after the applied change.

9

primaryKeyColumnNames

List of columns that compose the table’s primary key.

10

columns

Metadata for each column in the changed table.

11

attributes

Custom attribute metadata for each table change.

For more information, see schema history topic.

Snapshots

When a Debezium MySQL connector is first started, it performs an initial consistent snapshot of your database. This snapshot enables the connector to establish a baseline for the current state of the database.

Debezium can use different modes when it runs a snapshot. The snapshot mode is determined by the snapshot.mode configuration property. The default value of the property is initial. You can customize the way that the connector creates snapshots by changing the value of the snapshot.mode property.

The connector completes a series of tasks when it performs the snapshot. The exact steps vary with the snapshot mode and with the table locking policy that is in effect for the database. The Debezium MySQL connector completes different steps when it performs an initial snapshot that uses a global read lock or table-level locks.

Initial snapshots that use a global read lock

You can customize the way that the connector creates snapshots by changing the value of the snapshot.mode property. If you configure a different snapshot mode, the connector completes the snapshot by using a modified version of this workflow. For information about the snapshot process in environments that do not permit global read locks, see the snapshot workflow for table-level locks.

Default workflow that the Debezium MySQL connector uses to perform an initial snapshot with a global read lock

The following table shows the steps in the workflow that Debezium follows to create a snapshot with a global read lock.

StepAction

1

Establish a connection to the database.

2

Determine the tables to be captured. By default, the connector captures the data for all non-system tables. After the snapshot completes, the connector continues to stream data for the specified tables. If you want the connector to capture data only from specific tables you can direct the connector to capture the data for only a subset of tables or table elements by setting properties such as table.include.list or table.exclude.list.

3

Obtain a global read lock on the tables to be captured to block writes by other database clients.

The snapshot itself does not prevent other clients from applying DDL that might interfere with the connector’s attempt to read the binlog position and table schemas. The connector retains the global read lock while it reads the binlog position, and releases the lock as described in a later step.

4

Start a transaction with repeatable read semantics to ensure that all subsequent reads within the transaction are done against the consistent snapshot.

The use of these isolation semantics can slow the progress of the snapshot. If the snapshot takes too long to complete, consider using a different isolation configuration, or skip the initial snapshot and run an incremental snapshot instead.

5

Read the current binlog position.

6

Capture the structure of all tables in the database, or all tables that are designated for capture. The connector persists schema information in its internal database schema history topic, including all necessary DROP…​ and CREATE…​ DDL statements.
The schema history provides information about the structure that is in effect when a change event occurs.

By default, the connector captures the schema of every table in the database, including tables that are not configured for capture. If tables are not configured for capture, the initial snapshot captures only their structure; it does not capture any table data.

For more information about why snapshots persist schema information for tables that you did not include in the initial snapshot, see Understanding why initial snapshots capture the schema for all tables.

7

Release the global read lock obtained in Step 3. Other database clients can now write to the database.

8

At the binlog position that the connector read in Step 5, the connector begins to scan the tables that are designated for capture. During the scan, the connector completes the following tasks:

  1. Confirms that the table was created before the snapshot began. If the table was created after the snapshot began, the connector skips the table. After the snapshot is complete, and the connector transitions to streaming, it emits change events for any tables that were created after the snapshot began.

  2. Produces a read event for each row that is captured from a table. All read events contain the same binlog position, which is the position that was obtained in step 5.

  3. Emits each read event to the Kafka topic for the source table.

  4. Releases data table locks, if applicable.

9

Commit the transaction.

10

Record the successful completion of the snapshot in the connector offsets.

The resulting initial snapshot captures the current state of each row in the captured tables. From this baseline state, the connector captures subsequent changes as they occur.

After the snapshot process begins, if the process is interrupted due to connector failure, rebalancing, or other reasons, the process restarts after the connector restarts.

After the connector completes the initial snapshot, it continues streaming from the position that it read in Step 5 so that it does not miss any updates.

If the connector stops again for any reason, after it restarts, it resumes streaming changes from where it previously left off.

After the connector restarts, if the logs have been pruned, the connector’s position in the logs might no longer available. The connector then fails, and returns an error that indicates that a new snapshot is required. To configure the connector to automatically initiate a snapshot in this situation, set the value of the snapshot.mode property to when_needed. For more tips on troubleshooting the Debezium MySQL connector, see behavior when things go wrong.

Initial snapshots that use table-level locks

In some database environments administrators do not permit global read locks. If the Debezium MySQL connector detects that global read locks are not permitted, the connector uses table-level locks when it performs snapshots. For the connector to perform a snapshot that uses table-level locks, the database account that the Debezium connector uses to connect to MySQL must have LOCK TABLES privileges.

Default workflow that the Debezium MySQL connector uses to perform an initial snapshot with table-level locks

The following workflow lists the steps that Debezium takes to create a snapshot with table-level read locks. For information about the snapshot process in environments that do not permit global read locks, see the snapshot workflow for global read locks.

StepAction

1

Establish a connection to the database.

2

Determine the tables to be captured. By default, the connector captures all non-system tables. To have the connector capture a subset of tables or table elements, you can set a number of include and exclude properties to filter the data, for example, table.include.list or table.exclude.list.

3

Obtain table-level locks.

4

Start a transaction with repeatable read semantics to ensure that all subsequent reads within the transaction are done against the consistent snapshot.

5

Read the current binlog position.

6

Read the schema of the databases and tables for which the connector is configured to capture changes. The connector persists schema information in its internal database schema history topic, including all necessary DROP…​ and CREATE…​ DDL statements.
The schema history provides information about the structure that is in effect when a change event occurs.

By default, the connector captures the schema of every table in the database, including tables that are not configured for capture. If tables are not configured for capture, the initial snapshot captures only their structure; it does not capture any table data.

For more information about why snapshots persist schema information for tables that you did not include in the initial snapshot, see Understanding why initial snapshots capture the schema for all tables.

7

At the binlog position that the connector read in Step 5, the connector begins to scan the tables that are designated for capture. During the scan, the connector completes the following tasks:

  1. Confirms that the table was created before the snapshot began. If the table was created after the snapshot began, the connector skips the table. After the snapshot is complete, and the connector transitions to streaming, it emits change events for any tables that were created after the snapshot began.

  2. Produces a read event for each row that is captured from a table. All read events contain the same binlog position, which is the position that was obtained in step 5.

  3. Emits each read event to the Kafka topic for the source table.

  4. Releases data table locks, if applicable.

8

Commit the transaction.

9

Release the table-level locks. Other database clients can now write to any previously locked tables.

10

Record the successful completion of the snapshot in the connector offsets.

Understanding why initial snapshots capture the schema history for all tables

The initial snapshot that a connector runs captures two types of information:

Table data

Information about INSERT, UPDATE, and DELETE operations in tables that are named in the connector’s table.include.list property.

Schema data

DDL statements that describe the structural changes that are applied to tables. Schema data is persisted to both the internal schema history topic, and to the connector’s schema change topic, if one is configured.

After you run an initial snapshot, you might notice that the snapshot captures schema information for tables that are not designated for capture. By default, initial snapshots are designed to capture schema information for every table that is present in the database, not only from tables that are designated for capture. Connectors require that the table’s schema is present in the schema history topic before they can capture a table. By enabling the initial snapshot to capture schema data for tables that are not part of the original capture set, Debezium prepares the connector to readily capture event data from these tables should that later become necessary. If the initial snapshot does not capture a table’s schema, you must add the schema to the history topic before the connector can capture data from the table.

In some cases, you might want to limit schema capture in the initial snapshot. This can be useful when you want to reduce the time required to complete a snapshot. Or when Debezium connects to the database instance through a user account that has access to multiple logical databases, but you want the connector to capture changes only from tables in a specific logic database.

Additional information

Capturing data from tables not captured by the initial snapshot (no schema change)

In some cases, you might want the connector to capture data from a table whose schema was not captured by the initial snapshot. Depending on the connector configuration, the initial snapshot might capture the table schema only for specific tables in the database. If the table schema is not present in the history topic, the connector fails to capture the table, and reports a missing schema error.

You might still be able to capture data from the table, but you must perform additional steps to add the table schema.

Prerequisites

Procedure

  1. Stop the connector.

  2. Remove the internal database schema history topic that is specified by the schema.history.internal.kafka.topic property.

  3. Apply the following changes to the connector configuration:

    1. Set the snapshot.mode to schema_only_recovery.

    2. Set the value of schema.history.internal.store.only.captured.tables.ddl to false.

    3. Add the tables that you want the connector to capture to table.include.list. This guarantees that in the future, the connector can reconstruct the schema history for all tables.

  4. Restart the connector. The snapshot recovery process rebuilds the schema history based on the current structure of the tables.

  5. (Optional) After the snapshot completes, initiate an incremental snapshot to capture existing data for newly added tables along with changes to other tables that occurred while that connector was off-line.

  6. (Optional) Reset the snapshot.mode back to schema_only to prevent the connector from initiating recovery after a future restart.

Capturing data from tables not captured by the initial snapshot (schema change)

If a schema change is applied to a table, records that are committed before the schema change have different structures than those that were committed after the change. When Debezium captures data from a table, it reads the schema history to ensure that it applies the correct schema to each event. If the schema is not present in the schema history topic, the connector is unable to capture the table, and an error results.

If you want to capture data from a table that was not captured by the initial snapshot, and the schema of the table was modified, you must add the schema to the history topic, if it is not already available. You can add the schema by running a new schema snapshot, or by running an initial snapshot for the table.

Prerequisites

  • You want to capture data from a table with a schema that the connector did not capture during the initial snapshot.

  • A schema change was applied to the table so that the records to be captured do not have a uniform structure.

Procedure

Initial snapshot captured the schema for all tables (store.only.captured.tables.ddl was set to false)

  1. Edit the table.include.list property to specify the tables that you want to capture.

  2. Restart the connector.

  3. Initiate an incremental snapshot if you want to capture existing data from the newly added tables.

Initial snapshot did not capture the schema for all tables (store.only.captured.tables.ddl was set to true)

If the initial snapshot did not save the schema of the table that you want to capture, complete one of the following procedures:

  • Procedure 1: Schema snapshot, followed by incremental snapshot

    In this procedure, the connector first performs a schema snapshot. You can then initiate an incremental snapshot to enable the connector to synchronize data.

    1. Stop the connector.

    2. Remove the internal database schema history topic that is specified by the schema.history.internal.kafka.topic property.

    3. Clear the offsets in the configured Kafka Connect offset.storage.topic. For more information about how to remove offsets, see the Debezium community FAQ.

      Removing offsets should be performed only by advanced users who have experience in manipulating internal Kafka Connect data. This operation is potentially destructive, and should be performed only as a last resort.

    4. Set values for properties in the connector configuration as described in the following steps:

      1. Set the value of the snapshot.mode property to schema_only.

      2. Edit the table.include.list to add the tables that you want to capture.

    5. Restart the connector.

    6. Wait for Debezium to capture the schema of the new and existing tables. Data changes that occurred any tables after the connector stopped are not captured.

    7. To ensure that no data is lost, initiate an incremental snapshot.

    Procedure 2: Initial snapshot, followed by optional incremental snapshot

    In this procedure the connector performs a full initial snapshot of the database. As with any initial snapshot, in a database with many large tables, running an initial snapshot can be a time-consuming operation. After the snapshot completes, you can optionally trigger an incremental snapshot to capture any changes that occur while the connector is off-line.

    1. Stop the connector.

    2. Remove the internal database schema history topic that is specified by the schema.history.internal.kafka.topic property.

    3. Clear the offsets in the configured Kafka Connect offset.storage.topic. For more information about how to remove offsets, see the Debezium community FAQ.

      Removing offsets should be performed only by advanced users who have experience in manipulating internal Kafka Connect data. This operation is potentially destructive, and should be performed only as a last resort.

    4. Edit the table.include.list to add the tables that you want to capture.

    5. Set values for properties in the connector configuration as described in the following steps:

      1. Set the value of the snapshot.mode property to initial.

      2. (Optional) Set schema.history.internal.store.only.captured.tables.ddl to false.

    6. Restart the connector. The connector takes a full database snapshot. After the snapshot completes, the connector transitions to streaming.

    7. (Optional) To capture any data that changed while the connector was off-line, initiate an incremental snapshot.

Ad hoc snapshots

By default, a connector runs an initial snapshot operation only after it starts for the first time. Following this initial snapshot, under normal circumstances, the connector does not repeat the snapshot process. Any future change event data that the connector captures comes in through the streaming process only.

However, in some situations the data that the connector obtained during the initial snapshot might become stale, lost, or incomplete. To provide a mechanism for recapturing table data, Debezium includes an option to perform ad hoc snapshots. You might want to perform an ad hoc snapshot after any of the following changes occur in your Debezium environment:

  • The connector configuration is modified to capture a different set of tables.

  • Kafka topics are deleted and must be rebuilt.

  • Data corruption occurs due to a configuration error or some other problem.

You can re-run a snapshot for a table for which you previously captured a snapshot by initiating a so-called ad-hoc snapshot. Ad hoc snapshots require the use of signaling tables. You initiate an ad hoc snapshot by sending a signal request to the Debezium signaling table.

When you initiate an ad hoc snapshot of an existing table, the connector appends content to the topic that already exists for the table. If a previously existing topic was removed, Debezium can create a topic automatically if automatic topic creation is enabled.

Ad hoc snapshot signals specify the tables to include in the snapshot. The snapshot can capture the entire contents of the database, or capture only a subset of the tables in the database. Also, the snapshot can capture a subset of the contents of the table(s) in the database.

You specify the tables to capture by sending an execute-snapshot message to the signaling table. Set the type of the execute-snapshot signal to incremental or blocking, and provide the names of the tables to include in the snapshot, as described in the following table:

Table 2. Example of an ad hoc execute-snapshot signal record
FieldDefaultValue

type

incremental

Specifies the type of snapshot that you want to run.
Currently, you can request incremental or blocking snapshots.

data-collections

N/A

An array that contains regular expressions matching the fully-qualified names of the table to be snapshotted.
The format of the names is the same as for the signal.data.collection configuration option.

additional-condition

N/A

An optional string, which specifies a condition based on the column(s) of the table(s), to capture a subset of the contents of the table(s).

This property is deprecated. To specify criteria for defining the subset of data that you want the snapshot to capture, use the additional-conditions parameter.

additional-conditions

N/A

An optional array that specifies a set of additional conditions that the connector evaluates to determine the subset of records to include in a snapshot.
Each additional condition is an object that specifies the criteria for filtering the data that an ad hoc snapshot captures. You can set the following parameters for each additional condition:

    data-collection

    The fully-qualified name of the table that the filter applies to. You can apply different filters to each table.

    filter

    Specifies column values that must be present in a database record for the snapshot to include it, for example, “color=’blue’”.

    The values that you assign to the filter parameter are the same types of values that you might specify in the WHERE clause of SELECT statements when you set the snapshot.select.statement.overrides property for a blocking snapshot. In earlier Debezium releases, an explicit filter parameter was not defined for snapshot signals; instead, filter criteria were implied by the values that were specified for the now deprecated additional-condition parameter.

surrogate-key

N/A

An optional string that specifies the column name that the connector uses as the primary key of a table during the snapshot process.

Triggering an ad hoc incremental snapshot

You initiate an ad hoc incremental snapshot by adding an entry with the execute-snapshot signal type to the signaling table. After the connector processes the message, it begins the snapshot operation. The snapshot process reads the first and last primary key values and uses those values as the start and end point for each table. Based on the number of entries in the table, and the configured chunk size, Debezium divides the table into chunks, and proceeds to snapshot each chunk, in succession, one at a time.

For more information, see Incremental snapshots.

Triggering an ad hoc blocking snapshot

You initiate an ad hoc blocking snapshot by adding an entry with the execute-snapshot signal type to the signaling table. After the connector processes the message, it begins the snapshot operation. The connector temporarily stops streaming, and then initiates a snapshot of the specified table, following the same process that it uses during an initial snapshot. After the snapshot completes, the connector resumes streaming.

For more information, see Blocking snapshots.

Incremental snapshots

To provide flexibility in managing snapshots, Debezium includes a supplementary snapshot mechanism, known as incremental snapshotting. Incremental snapshots rely on the Debezium mechanism for sending signals to a Debezium connector. Incremental snapshots are based on the DDD-3 design document.

In an incremental snapshot, instead of capturing the full state of a database all at once, as in an initial snapshot, Debezium captures each table in phases, in a series of configurable chunks. You can specify the tables that you want the snapshot to capture and the size of each chunk. The chunk size determines the number of rows that the snapshot collects during each fetch operation on the database. The default chunk size for incremental snapshots is 1024 rows.

As an incremental snapshot proceeds, Debezium uses watermarks to track its progress, maintaining a record of each table row that it captures. This phased approach to capturing data provides the following advantages over the standard initial snapshot process:

  • You can run incremental snapshots in parallel with streamed data capture, instead of postponing streaming until the snapshot completes. The connector continues to capture near real-time events from the change log throughout the snapshot process, and neither operation blocks the other.

  • If the progress of an incremental snapshot is interrupted, you can resume it without losing any data. After the process resumes, the snapshot begins at the point where it stopped, rather than recapturing the table from the beginning.

  • You can run an incremental snapshot on demand at any time, and repeat the process as needed to adapt to database updates. For example, you might re-run a snapshot after you modify the connector configuration to add a table to its table.include.list property.

Incremental snapshot process

When you run an incremental snapshot, Debezium sorts each table by primary key and then splits the table into chunks based on the configured chunk size. Working chunk by chunk, it then captures each table row in a chunk. For each row that it captures, the snapshot emits a READ event. That event represents the value of the row when the snapshot for the chunk began.

As a snapshot proceeds, it’s likely that other processes continue to access the database, potentially modifying table records. To reflect such changes, INSERT, UPDATE, or DELETE operations are committed to the transaction log as per usual. Similarly, the ongoing Debezium streaming process continues to detect these change events and emits corresponding change event records to Kafka.

How Debezium resolves collisions among records with the same primary key

In some cases, the UPDATE or DELETE events that the streaming process emits are received out of sequence. That is, the streaming process might emit an event that modifies a table row before the snapshot captures the chunk that contains the READ event for that row. When the snapshot eventually emits the corresponding READ event for the row, its value is already superseded. To ensure that incremental snapshot events that arrive out of sequence are processed in the correct logical order, Debezium employs a buffering scheme for resolving collisions. Only after collisions between the snapshot events and the streamed events are resolved does Debezium emit an event record to Kafka.

Snapshot window

To assist in resolving collisions between late-arriving READ events and streamed events that modify the same table row, Debezium employs a so-called snapshot window. The snapshot windows demarcates the interval during which an incremental snapshot captures data for a specified table chunk. Before the snapshot window for a chunk opens, Debezium follows its usual behavior and emits events from the transaction log directly downstream to the target Kafka topic. But from the moment that the snapshot for a particular chunk opens, until it closes, Debezium performs a de-duplication step to resolve collisions between events that have the same primary key..

For each data collection, the Debezium emits two types of events, and stores the records for them both in a single destination Kafka topic. The snapshot records that it captures directly from a table are emitted as READ operations. Meanwhile, as users continue to update records in the data collection, and the transaction log is updated to reflect each commit, Debezium emits UPDATE or DELETE operations for each change.

As the snapshot window opens, and Debezium begins processing a snapshot chunk, it delivers snapshot records to a memory buffer. During the snapshot windows, the primary keys of the READ events in the buffer are compared to the primary keys of the incoming streamed events. If no match is found, the streamed event record is sent directly to Kafka. If Debezium detects a match, it discards the buffered READ event, and writes the streamed record to the destination topic, because the streamed event logically supersede the static snapshot event. After the snapshot window for the chunk closes, the buffer contains only READ events for which no related transaction log events exist. Debezium emits these remaining READ events to the table’s Kafka topic.

The connector repeats the process for each snapshot chunk.

Triggering an incremental snapshot

Currently, the only way to initiate an incremental snapshot is to send an ad hoc snapshot signal to the signaling table on the source database.

You submit a signal to the signaling table as SQL INSERT queries.

After Debezium detects the change in the signaling table, it reads the signal, and runs the requested snapshot operation.

The query that you submit specifies the tables to include in the snapshot, and, optionally, specifies the kind of snapshot operation. Currently, the only valid option for snapshots operations is the default value, incremental.

To specify the tables to include in the snapshot, provide a data-collections array that lists the tables or an array of regular expressions used to match tables, for example,

{"data-collections": ["public.MyFirstTable", "public.MySecondTable"]}

The data-collections array for an incremental snapshot signal has no default value. If the data-collections array is empty, Debezium detects that no action is required and does not perform a snapshot.

If the name of a table that you want to include in a snapshot contains a dot (.) in the name of the database, schema, or table, to add the table to the data-collections array, you must escape each part of the name in double quotes.

For example, to include a table that exists in the public schema and that has the name My.Table, use the following format: “public”.”My.Table”.

Prerequisites

Using a source signaling channel to trigger an incremental snapshot

  1. Send a SQL query to add the ad hoc incremental snapshot request to the signaling table:

    1. INSERT INTO <signalTable> (id, type, data) VALUES ('<id>', '<snapshotType>', '{"data-collections": ["<tableName>","<tableName>"],"type":"<snapshotType>","additional-conditions":[{"data-collection": "<tableName>", "filter": "<additional-condition>"}]}');

    For example,

    1. INSERT INTO myschema.debezium_signal (id, type, data) (1)
    2. values ('ad-hoc-1', (2)
    3. 'execute-snapshot', (3)
    4. '{"data-collections": ["schema1.table1", "schema2.table2"], (4)
    5. "type":"incremental", (5)
    6. "additional-conditions":[{"data-collection": "schema1.table1" ,"filter":"color=\'blue\'"}]}'); (6)

    The values of the id,type, and data parameters in the command correspond to the fields of the signaling table.

    The following table describes the parameters in the example:

    Table 3. Descriptions of fields in a SQL command for sending an incremental snapshot signal to the signaling table
    ItemValueDescription

    1

    myschema.debezium_signal

    Specifies the fully-qualified name of the signaling table on the source database.

    2

    ad-hoc-1

    The id parameter specifies an arbitrary string that is assigned as the id identifier for the signal request.
    Use this string to identify logging messages to entries in the signaling table. Debezium does not use this string. Rather, during the snapshot, Debezium generates its own id string as a watermarking signal.

    3

    execute-snapshot

    The type parameter specifies the operation that the signal is intended to trigger.

    4

    data-collections

    A required component of the data field of a signal that specifies an array of table names or regular expressions to match table names to include in the snapshot.
    The array lists regular expressions which match tables by their fully-qualified names, using the same format as you use to specify the name of the connector’s signaling table in the signal.data.collection configuration property.

    5

    incremental

    An optional type component of the data field of a signal that specifies the kind of snapshot operation to run.
    Currently, the only valid option is the default value, incremental.
    If you do not specify a value, the connector runs an incremental snapshot.

    6

    additional-conditions

    An optional array that specifies a set of additional conditions that the connector evaluates to determine the subset of records to include in a snapshot.
    Each additional condition is an object with data-collection and filter properties. You can specify different filters for each data collection.
    * The data-collection property is the fully-qualified name of the data collection for which the filter will be applied. For more information about the additional-conditions parameter, see Ad hoc incremental snapshots with additional-conditions.

Ad hoc incremental snapshots with additional-conditions

If you want a snapshot to include only a subset of the content in a table, you can modify the signal request by appending an additional-conditions parameter to the snapshot signal.

The SQL query for a typical snapshot takes the following form:

  1. SELECT * FROM <tableName> ....

By adding an additional-conditions parameter, you append a WHERE condition to the SQL query, as in the following example:

  1. SELECT * FROM <data-collection> WHERE <filter> ....

The following example shows a SQL query to send an ad hoc incremental snapshot request with an additional condition to the signaling table:

  1. INSERT INTO <signalTable> (id, type, data) VALUES ('<id>', '<snapshotType>', '{"data-collections": ["<tableName>","<tableName>"],"type":"<snapshotType>","additional-conditions":[{"data-collection": "<tableName>", "filter": "<additional-condition>"}]}');

For example, suppose you have a products table that contains the following columns:

  • id (primary key)

  • color

  • quantity

If you want an incremental snapshot of the products table to include only the data items where color=blue, you can use the following SQL statement to trigger the snapshot:

  1. INSERT INTO myschema.debezium_signal (id, type, data) VALUES('ad-hoc-1', 'execute-snapshot', '{"data-collections": ["schema1.products"],"type":"incremental", "additional-conditions":[{"data-collection": "schema1.products", "filter": "color=blue"}]}');

The additional-conditions parameter also enables you to pass conditions that are based on more than one column. For example, using the products table from the previous example, you can submit a query that triggers an incremental snapshot that includes the data of only those items for which color=blue and quantity>10:

  1. INSERT INTO myschema.debezium_signal (id, type, data) VALUES('ad-hoc-1', 'execute-snapshot', '{"data-collections": ["schema1.products"],"type":"incremental", "additional-conditions":[{"data-collection": "schema1.products", "filter": "color=blue AND quantity>10"}]}');

The following example, shows the JSON for an incremental snapshot event that is captured by a connector.

Example: Incremental snapshot event message

  1. {
  2. "before":null,
  3. "after": {
  4. "pk":"1",
  5. "value":"New data"
  6. },
  7. "source": {
  8. ...
  9. "snapshot":"incremental" (1)
  10. },
  11. "op":"r", (2)
  12. "ts_ms":"1620393591654",
  13. "transaction":null
  14. }
ItemField nameDescription

1

snapshot

Specifies the type of snapshot operation to run.
Currently, the only valid option is the default value, incremental.
Specifying a type value in the SQL query that you submit to the signaling table is optional.
If you do not specify a value, the connector runs an incremental snapshot.

2

op

Specifies the event type.
The value for snapshot events is r, signifying a READ operation.

Using the Kafka signaling channel to trigger an incremental snapshot

You can send a message to the configured Kafka topic to request the connector to run an ad hoc incremental snapshot.

The key of the Kafka message must match the value of the topic.prefix connector configuration option.

The value of the message is a JSON object with type and data fields.

The signal type is execute-snapshot, and the data field must have the following fields:

Table 4. Execute snapshot data fields
FieldDefaultValue

type

incremental

The type of the snapshot to be executed. Currently Debezium supports only the incremental type.
See the next section for more details.

data-collections

N/A

An array of comma-separated regular expressions that match the fully-qualified names of tables to include in the snapshot.
Specify the names by using the same format as is required for the signal.data.collection configuration option.

additional-condition

N/A

An optional string that specifies a condition that the connector evaluates to designate a subset of records to include in a snapshot.

This property is deprecated and should be replaced by the additional-conditions property.

additional-conditions

N/A

An optional array of additional conditions that specifies criteria that the connector evaluates to designate a subset of records to include in a snapshot.
Each additional condition is an object that specifies the criteria for filtering the data that an ad hoc snapshot captures. You can set the following parameters for each additional condition: data-collection:: The fully-qualified name of the table that the filter applies to. You can apply different filters to each table. filter:: Specifies column values that must be present in a database record for the snapshot to include it, for example, “color=’blue’”.

The values that you assign to the filter parameter are the same types of values that you might specify in the WHERE clause of SELECT statements when you set the snapshot.select.statement.overrides property for a blocking snapshot. In earlier Debezium releases, an explicit filter parameter was not defined for snapshot signals; instead, filter criteria were implied by the values that were specified for the now deprecated additional-condition parameter.

An example of the execute-snapshot Kafka message:

  1. Key = `test_connector`
  2. Value = `{"type":"execute-snapshot","data": {"data-collections": ["schema1.table1", "schema1.table2"], "type": "INCREMENTAL"}}`

Ad hoc incremental snapshots with additional-conditions

Debezium uses the additional-conditions field to select a subset of a table’s content.

Typically, when Debezium runs a snapshot, it runs a SQL query such as:

SELECT * FROM _<tableName>_ …​.

When the snapshot request includes an additional-conditions property, the data-collection and filter parameters of the property are appended to the SQL query, for example:

SELECT * FROM _<data-collection>_ WHERE _<filter>_ …​.

For example, given a products table with the columns id (primary key), color, and brand, if you want a snapshot to include only content for which color='blue', when you request the snapshot, you could add the additional-conditions property to filter the content:

  1. Key = `test_connector`
  2. Value = `{"type":"execute-snapshot","data": {"data-collections": ["schema1.products"], "type": "INCREMENTAL", "additional-conditions": [{"data-collection": "schema1.products" ,"filter":"color='blue'"}]}}`

You can use the additional-conditions property to pass conditions based on multiple columns. For example, using the same products table as in the previous example, if you want a snapshot to include only the content from the products table for which color='blue', and brand='MyBrand', you could send the following request:

  1. Key = `test_connector`
  2. Value = `{"type":"execute-snapshot","data": {"data-collections": ["schema1.products"], "type": "INCREMENTAL", "additional-conditions": [{"data-collection": "schema1.products" ,"filter":"color='blue' AND brand='MyBrand'"}]}}`

Stopping an incremental snapshot

You can also stop an incremental snapshot by sending a signal to the table on the source database. You submit a stop snapshot signal to the table by sending a SQL INSERT query.

After Debezium detects the change in the signaling table, it reads the signal, and stops the incremental snapshot operation if it’s in progress.

The query that you submit specifies the snapshot operation of incremental, and, optionally, the tables of the current running snapshot to be removed.

Prerequisites

Using a source signaling channel to stop an incremental snapshot

  1. Send a SQL query to stop the ad hoc incremental snapshot to the signaling table:

    1. INSERT INTO <signalTable> (id, type, data) values ('<id>', 'stop-snapshot', '{"data-collections": ["<tableName>","<tableName>"],"type":"incremental"}');

    For example,

    1. INSERT INTO myschema.debezium_signal (id, type, data) (1)
    2. values ('ad-hoc-1', (2)
    3. 'stop-snapshot', (3)
    4. '{"data-collections": ["schema1.table1", "schema2.table2"], (4)
    5. "type":"incremental"}'); (5)

    The values of the id, type, and data parameters in the signal command correspond to the fields of the signaling table.

    The following table describes the parameters in the example:

    Table 5. Descriptions of fields in a SQL command for sending a stop incremental snapshot signal to the signaling table
    ItemValueDescription

    1

    myschema.debezium_signal

    Specifies the fully-qualified name of the signaling table on the source database.

    2

    ad-hoc-1

    The id parameter specifies an arbitrary string that is assigned as the id identifier for the signal request.
    Use this string to identify logging messages to entries in the signaling table. Debezium does not use this string.

    3

    stop-snapshot

    Specifies type parameter specifies the operation that the signal is intended to trigger.

    4

    data-collections

    An optional component of the data field of a signal that specifies an array of table names or regular expressions to match table names to remove from the snapshot.
    The array lists regular expressions which match tables by their fully-qualified names, using the same format as you use to specify the name of the connector’s signaling table in the signal.data.collection configuration property. If this component of the data field is omitted, the signal stops the entire incremental snapshot that is in progress.

    5

    incremental

    A required component of the data field of a signal that specifies the kind of snapshot operation that is to be stopped.
    Currently, the only valid option is incremental.
    If you do not specify a type value, the signal fails to stop the incremental snapshot.

Using the Kafka signaling channel to stop an incremental snapshot

You can send a signal message to the configured Kafka signaling topic to stop an ad hoc incremental snapshot.

The key of the Kafka message must match the value of the topic.prefix connector configuration option.

The value of the message is a JSON object with type and data fields.

The signal type is stop-snapshot, and the data field must have the following fields:

Table 6. Execute snapshot data fields
FieldDefaultValue

type

incremental

The type of the snapshot to be executed. Currently Debezium supports only the incremental type.
See the next section for more details.

data-collections

N/A

An optional array of comma-separated regular expressions that match the fully-qualified names of the tables to include in the snapshot.
Specify the names by using the same format as is required for the signal.data.collection configuration option.

The following example shows a typical stop-snapshot Kafka message:

  1. Key = `test_connector`
  2. Value = `{"type":"stop-snapshot","data": {"data-collections": ["schema1.table1", "schema1.table2"], "type": "INCREMENTAL"}}`

Read-only incremental snapshots

The MySQL connector allows for running incremental snapshots with a read-only connection to the database. To run an incremental snapshot with read-only access, the connector uses the executed global transaction IDs (GTID) set as high and low watermarks. The state of a chunk’s window is updated by comparing the GTIDs of binary log (binlog) events or the server’s heartbeats against low and high watermarks.

To switch to a read-only implementation, set the value of the read.only property to true.

Prerequisites

  • Enable MySQL GTIDs.

  • If the connector reads from a multi-threaded replica (that is, a replica for which the value of replica_parallel_workers is greater than 0) you must set one of the following options:

    • replica_preserve_commit_order=ON

    • slave_preserve_commit_order=ON

Ad hoc read-only incremental snapshots

When the MySQL connection is read-only, you can use any of the available signaling channels without the requirement to use the source channel.

Operation type of snapshot events

The MySQL connector emits snapshot events as READ operations ("op" : "r"). If you prefer that the connector emits snapshot events as CREATE (c) events, configure the Debezium ReadToInsertEvent single message transform (SMT) to modify the event type.

The following example shows how to configure the SMT:

Example: Using the ReadToInsertEvent SMT to change the type of snapshot events

  1. transforms=snapshotasinsert,...
  2. transforms.snapshotasinsert.type=io.debezium.connector.mysql.transforms.ReadToInsertEvent

Blocking snapshots

To provide more flexibility in managing snapshots, Debezium includes a supplementary ad hoc snapshot mechanism, known as a blocking snapshot. Blocking snapshots rely on the Debezium mechanism for sending signals to a Debezium connector.

A blocking snapshot behaves just like an initial snapshot, except that you can trigger it at run time.

You might want to run a blocking snapshot rather than use the standard initial snapshot process in the following situations:

  • You add a new table and you want to complete the snapshot while the connector is running.

  • You add a large table, and you want the snapshot to complete in less time than is possible with an incremental snapshot.

Blocking snapshot process

When you run a blocking snapshot, Debezium stops streaming, and then initiates a snapshot of the specified table, following the same process that it uses during an initial snapshot. After the snapshot completes, the streaming is resumed.

Configure snapshot

You can set the following properties in the data component of a signal:

  • data-collections: to specify which tables must be snapshot

  • additional-conditions: You can specify different filters for different table.

    • The data-collection property is the fully-qualified name of the table for which the filter will be applied.

    • The filter property will have the same value used in the snapshot.select.statement.overrides

For example:

  1. {"type": "blocking", "data-collections": ["schema1.table1", "schema1.table2"], "additional-conditions": [{"data-collection": "schema1.table1", "filter": "SELECT * FROM [schema1].[table1] WHERE column1 = 0 ORDER BY column2 DESC"}, {"data-collection": "schema1.table2", "filter": "SELECT * FROM [schema1].[table2] WHERE column2 > 0"}]}

Possible duplicates

A delay might exist between the time that you send the signal to trigger the snapshot, and the time when streaming stops and the snapshot starts. As a result of this delay, after the snapshot completes, the connector might emit some event records that duplicate records captured by the snapshot.

Topic names

By default, the MySQL connector writes change events for all of the INSERT, UPDATE, and DELETE operations that occur in a table to a single Apache Kafka topic that is specific to that table.

The connector uses the following convention to name change event topics:

topicPrefix.databaseName.tableName

Suppose that fulfillment is the topic prefix, inventory is the database name, and the database contains tables named orders, customers, and products. The Debezium MySQL connector emits events to three Kafka topics, one for each table in the database:

  1. fulfillment.inventory.orders
  2. fulfillment.inventory.customers
  3. fulfillment.inventory.products

The following list provides definitions for the components of the default name:

topicPrefix

The topic prefix as specified by the topic.prefix connector configuration property.

schemaName

The name of the schema in which the operation occurred.

tableName

The name of the table in which the operation occurred.

The connector applies similar naming conventions to label its internal database schema history topics, schema change topics, and transaction metadata topics.

If the default topic name do not meet your requirements, you can configure custom topic names. To configure custom topic names, you specify regular expressions in the logical topic routing SMT. For more information about using the logical topic routing SMT to customize topic naming, see Topic routing.

Transaction metadata

Debezium can generate events that represent transaction boundaries and that enrich data change event messages.

Limits on when Debezium receives transaction metadata

Debezium registers and receives metadata only for transactions that occur after you deploy the connector. Metadata for transactions that occur before you deploy the connector is not available.

Debezium generates transaction boundary events for the BEGIN and END delimiters in every transaction. Transaction boundary events contain the following fields:

status

BEGIN or END.

id

String representation of the unique transaction identifier.

ts_ms

The time of a transaction boundary event (BEGIN or END event) at the data source. If the data source does not provide Debezium with the event time, then the field instead represents the time at which Debezium processes the event.

event_count (for END events)

Total number of events emitted by the transaction.

data_collections (for END events)

An array of pairs of data_collection and event_count elements that indicates the number of events that the connector emits for changes that originate from a data collection.

Example

  1. {
  2. "status": "BEGIN",
  3. "id": "0e4d5dcd-a33b-11ea-80f1-02010a22a99e:10",
  4. "ts_ms": 1486500577125,
  5. "event_count": null,
  6. "data_collections": null
  7. }
  8. {
  9. "status": "END",
  10. "id": "0e4d5dcd-a33b-11ea-80f1-02010a22a99e:10",
  11. "ts_ms": 1486500577691,
  12. "event_count": 2,
  13. "data_collections": [
  14. {
  15. "data_collection": "s1.a",
  16. "event_count": 1
  17. },
  18. {
  19. "data_collection": "s2.a",
  20. "event_count": 1
  21. }
  22. ]
  23. }

Unless overridden via the topic.transaction option, the connector emits transaction events to the .transaction topic.

Change data event enrichment

When transaction metadata is enabled the data message Envelope is enriched with a new transaction field. This field provides information about every event in the form of a composite of fields:

id

String representation of unique transaction identifier.

total_order

The absolute position of the event among all events generated by the transaction.

data_collection_order

The per-data collection position of the event among all events that were emitted by the transaction.

Following is an example of a message:

  1. {
  2. "before": null,
  3. "after": {
  4. "pk": "2",
  5. "aa": "1"
  6. },
  7. "source": {
  8. ...
  9. },
  10. "op": "c",
  11. "ts_ms": "1580390884335",
  12. "transaction": {
  13. "id": "0e4d5dcd-a33b-11ea-80f1-02010a22a99e:10",
  14. "total_order": "1",
  15. "data_collection_order": "1"
  16. }
  17. }

For systems which don’t have GTID enabled, the transaction identifier is constructed using the combination of binlog filename and binlog position. For example, if the binlog filename and position corresponding to the transaction BEGIN event are mysql-bin.000002 and 1913 respectively then the Debezium constructed transaction identifier would be file=mysql-bin.000002,pos=1913.

Data change events

The Debezium MySQL connector generates a data change event for each row-level INSERT, UPDATE, and DELETE operation. Each event contains a key and a value. The structure of the key and the value depends on the table that was changed.

Debezium and Kafka Connect are designed around continuous streams of event messages. However, the structure of these events may change over time, which can be difficult for consumers to handle. To address this, each event contains the schema for its content or, if you are using a schema registry, a schema ID that a consumer can use to obtain the schema from the registry. This makes each event self-contained.

The following skeleton JSON shows the basic four parts of a change event. However, how you configure the Kafka Connect converter that you choose to use in your application determines the representation of these four parts in change events. A schema field is in a change event only when you configure the converter to produce it. Likewise, the event key and event payload are in a change event only if you configure a converter to produce it. If you use the JSON converter and you configure it to produce all four basic change event parts, change events have this structure:

  1. {
  2. "schema": { (1)
  3. ...
  4. },
  5. "payload": { (2)
  6. ...
  7. },
  8. "schema": { (3)
  9. ...
  10. },
  11. "payload": { (4)
  12. ...
  13. },
  14. }
Table 7. Overview of change event basic content
ItemField nameDescription

1

schema

The first schema field is part of the event key. It specifies a Kafka Connect schema that describes what is in the event key’s payload portion. In other words, the first schema field describes the structure of the primary key, or the unique key if the table does not have a primary key, for the table that was changed.

It is possible to override the table’s primary key by setting the message.key.columns connector configuration property. In this case, the first schema field describes the structure of the key identified by that property.

2

payload

The first payload field is part of the event key. It has the structure described by the previous schema field and it contains the key for the row that was changed.

3

schema

The second schema field is part of the event value. It specifies the Kafka Connect schema that describes what is in the event value’s payload portion. In other words, the second schema describes the structure of the row that was changed. Typically, this schema contains nested schemas.

4

payload

The second payload field is part of the event value. It has the structure described by the previous schema field and it contains the actual data for the row that was changed.

By default, the connector streams change event records to topics with names that are the same as the event’s originating table. See topic names.

The MySQL connector ensures that all Kafka Connect schema names adhere to the Avro schema name format. This means that the logical server name must start with a Latin letter or an underscore, that is, a-z, A-Z, or . Each remaining character in the logical server name and each character in the database and table names must be a Latin letter, a digit, or an underscore, that is, a-z, A-Z, 0-9, or . If there is an invalid character it is replaced with an underscore character.

This can lead to unexpected conflicts if the logical server name, a database name, or a table name contains invalid characters, and the only characters that distinguish names from one another are invalid and thus replaced with underscores.

Change event keys

A change event’s key contains the schema for the changed table’s key and the changed row’s actual key. Both the schema and its corresponding payload contain a field for each column in the changed table’s PRIMARY KEY (or unique constraint) at the time the connector created the event.

Consider the following customers table, which is followed by an example of a change event key for this table.

  1. CREATE TABLE customers (
  2. id INTEGER NOT NULL AUTO_INCREMENT PRIMARY KEY,
  3. first_name VARCHAR(255) NOT NULL,
  4. last_name VARCHAR(255) NOT NULL,
  5. email VARCHAR(255) NOT NULL UNIQUE KEY
  6. ) AUTO_INCREMENT=1001;

Every change event that captures a change to the customers table has the same event key schema. For as long as the customers table has the previous definition, every change event that captures a change to the customers table has the following key structure. In JSON, it looks like this:

  1. {
  2. "schema": { (1)
  3. "type": "struct",
  4. "name": "mysql-server-1.inventory.customers.Key", (2)
  5. "optional": false, (3)
  6. "fields": [ (4)
  7. {
  8. "field": "id",
  9. "type": "int32",
  10. "optional": false
  11. }
  12. ]
  13. },
  14. "payload": { (5)
  15. "id": 1001
  16. }
  17. }
Table 8. Description of change event key
ItemField nameDescription

1

schema

The schema portion of the key specifies a Kafka Connect schema that describes what is in the key’s payload portion.

2

mysql-server-1.inventory.customers.Key

Name of the schema that defines the structure of the key’s payload. This schema describes the structure of the primary key for the table that was changed. Key schema names have the format connector-name.database-name.table-name.Key. In this example:

  • mysql-server-1 is the name of the connector that generated this event.

  • inventory is the database that contains the table that was changed.

  • customers is the table that was updated.

3

optional

Indicates whether the event key must contain a value in its payload field. In this example, a value in the key’s payload is required. A value in the key’s payload field is optional when a table does not have a primary key.

4

fields

Specifies each field that is expected in the payload, including each field’s name, type, and whether it is required.

5

payload

Contains the key for the row for which this change event was generated. In this example, the key, contains a single id field whose value is 1001.

Change event values

The value in a change event is a bit more complicated than the key. Like the key, the value has a schema section and a payload section. The schema section contains the schema that describes the Envelope structure of the payload section, including its nested fields. Change events for operations that create, update or delete data all have a value payload with an envelope structure.

Consider the same sample table that was used to show an example of a change event key:

  1. CREATE TABLE customers (
  2. id INTEGER NOT NULL AUTO_INCREMENT PRIMARY KEY,
  3. first_name VARCHAR(255) NOT NULL,
  4. last_name VARCHAR(255) NOT NULL,
  5. email VARCHAR(255) NOT NULL UNIQUE KEY
  6. ) AUTO_INCREMENT=1001;

The value portion of a change event for a change to this table is described for:

create events

The following example shows the value portion of a change event that the connector generates for an operation that creates data in the customers table:

  1. {
  2. "schema": { (1)
  3. "type": "struct",
  4. "fields": [
  5. {
  6. "type": "struct",
  7. "fields": [
  8. {
  9. "type": "int32",
  10. "optional": false,
  11. "field": "id"
  12. },
  13. {
  14. "type": "string",
  15. "optional": false,
  16. "field": "first_name"
  17. },
  18. {
  19. "type": "string",
  20. "optional": false,
  21. "field": "last_name"
  22. },
  23. {
  24. "type": "string",
  25. "optional": false,
  26. "field": "email"
  27. }
  28. ],
  29. "optional": true,
  30. "name": "mysql-server-1.inventory.customers.Value", (2)
  31. "field": "before"
  32. },
  33. {
  34. "type": "struct",
  35. "fields": [
  36. {
  37. "type": "int32",
  38. "optional": false,
  39. "field": "id"
  40. },
  41. {
  42. "type": "string",
  43. "optional": false,
  44. "field": "first_name"
  45. },
  46. {
  47. "type": "string",
  48. "optional": false,
  49. "field": "last_name"
  50. },
  51. {
  52. "type": "string",
  53. "optional": false,
  54. "field": "email"
  55. }
  56. ],
  57. "optional": true,
  58. "name": "mysql-server-1.inventory.customers.Value",
  59. "field": "after"
  60. },
  61. {
  62. "type": "struct",
  63. "fields": [
  64. {
  65. "type": "string",
  66. "optional": false,
  67. "field": "version"
  68. },
  69. {
  70. "type": "string",
  71. "optional": false,
  72. "field": "connector"
  73. },
  74. {
  75. "type": "string",
  76. "optional": false,
  77. "field": "name"
  78. },
  79. {
  80. "type": "int64",
  81. "optional": false,
  82. "field": "ts_ms"
  83. },
  84. {
  85. "type": "boolean",
  86. "optional": true,
  87. "default": false,
  88. "field": "snapshot"
  89. },
  90. {
  91. "type": "string",
  92. "optional": false,
  93. "field": "db"
  94. },
  95. {
  96. "type": "string",
  97. "optional": true,
  98. "field": "table"
  99. },
  100. {
  101. "type": "int64",
  102. "optional": false,
  103. "field": "server_id"
  104. },
  105. {
  106. "type": "string",
  107. "optional": true,
  108. "field": "gtid"
  109. },
  110. {
  111. "type": "string",
  112. "optional": false,
  113. "field": "file"
  114. },
  115. {
  116. "type": "int64",
  117. "optional": false,
  118. "field": "pos"
  119. },
  120. {
  121. "type": "int32",
  122. "optional": false,
  123. "field": "row"
  124. },
  125. {
  126. "type": "int64",
  127. "optional": true,
  128. "field": "thread"
  129. },
  130. {
  131. "type": "string",
  132. "optional": true,
  133. "field": "query"
  134. }
  135. ],
  136. "optional": false,
  137. "name": "io.debezium.connector.mysql.Source", (3)
  138. "field": "source"
  139. },
  140. {
  141. "type": "string",
  142. "optional": false,
  143. "field": "op"
  144. },
  145. {
  146. "type": "int64",
  147. "optional": true,
  148. "field": "ts_ms"
  149. }
  150. ],
  151. "optional": false,
  152. "name": "mysql-server-1.inventory.customers.Envelope" (4)
  153. },
  154. "payload": { (5)
  155. "op": "c", (6)
  156. "ts_ms": 1465491411815, (7)
  157. "before": null, (8)
  158. "after": { (9)
  159. "id": 1004,
  160. "first_name": "Anne",
  161. "last_name": "Kretchmar",
  162. "email": "annek@noanswer.org"
  163. },
  164. "source": { (10)
  165. "version": "2.5.4.Final",
  166. "connector": "mysql",
  167. "name": "mysql-server-1",
  168. "ts_ms": 0,
  169. "snapshot": false,
  170. "db": "inventory",
  171. "table": "customers",
  172. "server_id": 0,
  173. "gtid": null,
  174. "file": "mysql-bin.000003",
  175. "pos": 154,
  176. "row": 0,
  177. "thread": 7,
  178. "query": "INSERT INTO customers (first_name, last_name, email) VALUES ('Anne', 'Kretchmar', 'annek@noanswer.org')"
  179. }
  180. }
  181. }
Table 9. Descriptions of create event value fields
ItemField nameDescription

1

schema

The value’s schema, which describes the structure of the value’s payload. A change event’s value schema is the same in every change event that the connector generates for a particular table.

2

name

In the schema section, each name field specifies the schema for a field in the value’s payload.

mysql-server-1.inventory.customers.Value is the schema for the payload’s before and after fields. This schema is specific to the customers table.

Names of schemas for before and after fields are of the form logicalName.tableName.Value, which ensures that the schema name is unique in the database. This means that when using the Avro converter, the resulting Avro schema for each table in each logical source has its own evolution and history.

3

name

io.debezium.connector.mysql.Source is the schema for the payload’s source field. This schema is specific to the MySQL connector. The connector uses it for all events that it generates.

4

name

mysql-server-1.inventory.customers.Envelope is the schema for the overall structure of the payload, where mysql-server-1 is the connector name, inventory is the database, and customers is the table.

5

payload

The value’s actual data. This is the information that the change event is providing.

It may appear that the JSON representations of the events are much larger than the rows they describe. This is because the JSON representation must include the schema and the payload portions of the message. However, by using the Avro converter, you can significantly decrease the size of the messages that the connector streams to Kafka topics.

6

op

Mandatory string that describes the type of operation that caused the connector to generate the event. In this example, c indicates that the operation created a row. Valid values are:

  • c = create

  • u = update

  • d = delete

  • r = read (applies to only snapshots)

7

ts_ms

Optional field that displays the time at which the connector processed the event. The time is based on the system clock in the JVM running the Kafka Connect task.

In the source object, ts_ms indicates the time that the change was made in the database. By comparing the value for payload.source.ts_ms with the value for payload.ts_ms, you can determine the lag between the source database update and Debezium.

8

before

An optional field that specifies the state of the row before the event occurred. When the op field is c for create, as it is in this example, the before field is null since this change event is for new content.

9

after

An optional field that specifies the state of the row after the event occurred. In this example, the after field contains the values of the new row’s id, first_name, last_name, and email columns.

10

source

Mandatory field that describes the source metadata for the event. This field contains information that you can use to compare this event with other events, with regard to the origin of the events, the order in which the events occurred, and whether events were part of the same transaction. The source metadata includes:

  • Debezium version

  • Connector name

  • binlog name where the event was recorded

  • binlog position

  • Row within the event

  • If the event was part of a snapshot

  • Name of the database and table that contain the new row

  • ID of the MySQL thread that created the event (non-snapshot only)

  • MySQL server ID (if available)

  • Timestamp for when the change was made in the database

If the MariaDB MySQL configuration option is enabled and the connector configuration include.query property is enabled, the source field also provides the query field, which contains the original SQL statement that caused the change event. On MariaDB, the configuration option is binlog_annotate_row_events.

update events

The value of a change event for an update in the sample customers table has the same schema as a create event for that table. Likewise, the event value’s payload has the same structure. However, the event value payload contains different values in an update event. Here is an example of a change event value in an event that the connector generates for an update in the customers table:

  1. {
  2. "schema": { ... },
  3. "payload": {
  4. "before": { (1)
  5. "id": 1004,
  6. "first_name": "Anne",
  7. "last_name": "Kretchmar",
  8. "email": "annek@noanswer.org"
  9. },
  10. "after": { (2)
  11. "id": 1004,
  12. "first_name": "Anne Marie",
  13. "last_name": "Kretchmar",
  14. "email": "annek@noanswer.org"
  15. },
  16. "source": { (3)
  17. "version": "2.5.4.Final",
  18. "name": "mysql-server-1",
  19. "connector": "mysql",
  20. "name": "mysql-server-1",
  21. "ts_ms": 1465581029100,
  22. "snapshot": false,
  23. "db": "inventory",
  24. "table": "customers",
  25. "server_id": 223344,
  26. "gtid": null,
  27. "file": "mysql-bin.000003",
  28. "pos": 484,
  29. "row": 0,
  30. "thread": 7,
  31. "query": "UPDATE customers SET first_name='Anne Marie' WHERE id=1004"
  32. },
  33. "op": "u", (4)
  34. "ts_ms": 1465581029523 (5)
  35. }
  36. }
Table 10. Descriptions of update event value fields
ItemField nameDescription

1

before

An optional field that specifies the state of the row before the event occurred. In an update event value, the before field contains a field for each table column and the value that was in that column before the database commit. In this example, the first_name value is Anne.

2

after

An optional field that specifies the state of the row after the event occurred. You can compare the before and after structures to determine what the update to this row was. In the example, the first_name value is now Anne Marie.

3

source

Mandatory field that describes the source metadata for the event. The source field structure has the same fields as in a create event, but some values are different, for example, the sample update event is from a different position in the binlog. The source metadata includes:

  • Debezium version

  • Connector name

  • binlog name where the event was recorded

  • binlog position

  • Row within the event

  • If the event was part of a snapshot

  • Name of the database and table that contain the updated row

  • ID of the MySQL thread that created the event (non-snapshot only)

  • MySQL server ID (if available)

  • Timestamp for when the change was made in the database

If the binlog_rows_query_log_events MySQL configuration option is enabled and the connector configuration include.query property is enabled, the source field also provides the query field, which contains the original SQL statement that caused the change event. On MariaDB, the configuration option is binlog_annotate_row_events.

4

op

Mandatory string that describes the type of operation. In an update event value, the op field value is u, signifying that this row changed because of an update.

5

ts_ms

Optional field that displays the time at which the connector processed the event. The time is based on the system clock in the JVM running the Kafka Connect task.

In the source object, ts_ms indicates the time that the change was made in the database. By comparing the value for payload.source.ts_ms with the value for payload.ts_ms, you can determine the lag between the source database update and Debezium.

Updating the columns for a row’s primary/unique key changes the value of the row’s key. When a key changes, Debezium outputs three events: a DELETE event and a tombstone event with the old key for the row, followed by an event with the new key for the row. Details are in the next section.

Primary key updates

An UPDATE operation that changes a row’s primary key field(s) is known as a primary key change. For a primary key change, in place of an UPDATE event record, the connector emits a DELETE event record for the old key and a CREATE event record for the new (updated) key. These events have the usual structure and content, and in addition, each one has a message header related to the primary key change:

  • The DELETE event record has __debezium.newkey as a message header. The value of this header is the new primary key for the updated row.

  • The CREATE event record has __debezium.oldkey as a message header. The value of this header is the previous (old) primary key that the updated row had.

delete events

The value in a delete change event has the same schema portion as create and update events for the same table. The payload portion in a delete event for the sample customers table looks like this:

  1. {
  2. "schema": { ... },
  3. "payload": {
  4. "before": { (1)
  5. "id": 1004,
  6. "first_name": "Anne Marie",
  7. "last_name": "Kretchmar",
  8. "email": "annek@noanswer.org"
  9. },
  10. "after": null, (2)
  11. "source": { (3)
  12. "version": "2.5.4.Final",
  13. "connector": "mysql",
  14. "name": "mysql-server-1",
  15. "ts_ms": 1465581902300,
  16. "snapshot": false,
  17. "db": "inventory",
  18. "table": "customers",
  19. "server_id": 223344,
  20. "gtid": null,
  21. "file": "mysql-bin.000003",
  22. "pos": 805,
  23. "row": 0,
  24. "thread": 7,
  25. "query": "DELETE FROM customers WHERE id=1004"
  26. },
  27. "op": "d", (4)
  28. "ts_ms": 1465581902461 (5)
  29. }
  30. }
Table 11. Descriptions of delete event value fields
ItemField nameDescription

1

before

Optional field that specifies the state of the row before the event occurred. In a delete event value, the before field contains the values that were in the row before it was deleted with the database commit.

2

after

Optional field that specifies the state of the row after the event occurred. In a delete event value, the after field is null, signifying that the row no longer exists.

3

source

Mandatory field that describes the source metadata for the event. In a delete event value, the source field structure is the same as for create and update events for the same table. Many source field values are also the same. In a delete event value, the ts_ms and pos field values, as well as other values, might have changed. But the source field in a delete event value provides the same metadata:

  • Debezium version

  • Connector name

  • binlog name where the event was recorded

  • binlog position

  • Row within the event

  • If the event was part of a snapshot

  • Name of the database and table that contain the updated row

  • ID of the MySQL thread that created the event (non-snapshot only)

  • MySQL server ID (if available)

  • Timestamp for when the change was made in the database

If the binlog_rows_query_log_events MySQL configuration option is enabled and the connector configuration include.query property is enabled, the source field also provides the query field, which contains the original SQL statement that caused the change event. On MariaDB, the configuration option is binlog_annotate_row_events.

4

op

Mandatory string that describes the type of operation. The op field value is d, signifying that this row was deleted.

5

ts_ms

Optional field that displays the time at which the connector processed the event. The time is based on the system clock in the JVM running the Kafka Connect task.

In the source object, ts_ms indicates the time that the change was made in the database. By comparing the value for payload.source.ts_ms with the value for payload.ts_ms, you can determine the lag between the source database update and Debezium.

A delete change event record provides a consumer with the information it needs to process the removal of this row. The old values are included because some consumers might require them in order to properly handle the removal.

MySQL connector events are designed to work with Kafka log compaction. Log compaction enables removal of some older messages as long as at least the most recent message for every key is kept. This lets Kafka reclaim storage space while ensuring that the topic contains a complete data set and can be used for reloading key-based state.

Tombstone events

When a row is deleted, the delete event value still works with log compaction, because Kafka can remove all earlier messages that have that same key. However, for Kafka to remove all messages that have that same key, the message value must be null. To make this possible, after Debezium’s MySQL connector emits a delete event, the connector emits a special tombstone event that has the same key but a null value.

truncate events

A truncate change event signals that a table has been truncated. The message key is null in this case, the message value looks like this:

  1. {
  2. "schema": { ... },
  3. "payload": {
  4. "source": { (1)
  5. "version": "2.5.4.Final",
  6. "name": "mysql-server-1",
  7. "connector": "mysql",
  8. "name": "mysql-server-1",
  9. "ts_ms": 1465581029100,
  10. "snapshot": false,
  11. "db": "inventory",
  12. "table": "customers",
  13. "server_id": 223344,
  14. "gtid": null,
  15. "file": "mysql-bin.000003",
  16. "pos": 484,
  17. "row": 0,
  18. "thread": 7,
  19. "query": "UPDATE customers SET first_name='Anne Marie' WHERE id=1004"
  20. },
  21. "op": "t", (2)
  22. "ts_ms": 1465581029523 (3)
  23. }
  24. }
Table 12. Descriptions of truncate event value fields
ItemField nameDescription

1

source

Mandatory field that describes the source metadata for the event. In a truncate event value, the source field structure is the same as for create, update, and delete events for the same table, provides this metadata:

  • Debezium version

  • Connector type and name

  • Binlog name where the event was recorded

  • Binlog position

  • Row within the event

  • If the event was part of a snapshot

  • Name of the database and table

  • ID of the MySQL thread that truncated the event (non-snapshot only)

  • MySQL server ID (if available)

  • Timestamp for when the change was made in the database

2

op

Mandatory string that describes the type of operation. The op field value is t, signifying that this table was truncated.

3

ts_ms

Optional field that displays the time at which the connector processed the event. The time is based on the system clock in the JVM running the Kafka Connect task.

+ In the source object, ts_ms indicates the time that the change was made in the database. By comparing the value for payload.source.ts_ms with the value for payload.ts_ms, you can determine the lag between the source database update and Debezium.

In case a single TRUNCATE statement applies to multiple tables, one truncate change event record for each truncated table will be emitted.

Note that since truncate events represent a change made to an entire table and don’t have a message key, unless you’re working with topics with a single partition, there are no ordering guarantees for the change events pertaining to a table (create, update, etc.) and truncate events for that table. For instance a consumer may receive an update event only after a truncate event for that table, when those events are read from different partitions.

Data type mappings

The Debezium MySQL connector represents changes to rows with events that are structured like the table in which the row exists. The event contains a field for each column value. The MySQL data type of that column dictates how Debezium represents the value in the event.

Columns that store strings are defined in MySQL with a character set and collation. The MySQL connector uses the column’s character set when reading the binary representation of the column values in the binlog events.

The connector can map MySQL data types to both literal and semantic types.

  • Literal type: how the value is represented using Kafka Connect schema types.

  • Semantic type: how the Kafka Connect schema captures the meaning of the field (schema name).

If the default data type conversions do not meet your needs, you can create a custom converter for the connector.

Basic types

The following table shows how the connector maps basic MySQL data types.

Table 13. Descriptions of basic type mappings
MySQL typeLiteral typeSemantic type

BOOLEAN, BOOL

BOOLEAN

n/a

BIT(1)

BOOLEAN

n/a

BIT(>1)

BYTES

io.debezium.data.Bits
The length schema parameter contains an integer that represents the number of bits. The byte[] contains the bits in little-endian form and is sized to contain the specified number of bits. For example, where n is bits:
numBytes = n/8 + (n%8== 0 ? 0 : 1)

TINYINT

INT16

n/a

SMALLINT[(M)]

INT16

n/a

MEDIUMINT[(M)]

INT32

n/a

INT, INTEGER[(M)]

INT32

n/a

BIGINT[(M)]

INT64

n/a

REAL[(M,D)]

FLOAT32

n/a

FLOAT[(P)]

FLOAT32 or FLOAT64

The precision is used only to determine storage size. A precision P from 0 to 23 results in a 4-byte single-precision FLOAT32 column. A precision P from 24 to 53 results in an 8-byte double-precision FLOAT64 column.

FLOAT(M,D)

FLOAT64

As of MySQL 8.0.17, the nonstandard FLOAT(M,D) and DOUBLE(M,D) syntax is deprecated, and should expect support for it be removed in a future version of MySQL, set FLOAT64 as default.

DOUBLE[(M,D)]

FLOAT64

n/a

CHAR(M)]

STRING

n/a

VARCHAR(M)]

STRING

n/a

BINARY(M)]

BYTES or STRING

n/a
Either the raw bytes (the default), a base64-encoded String, or a base64-url-safe-encoded String, or a hex-encoded String, based on the binary.handling.mode connector configuration property setting.

VARBINARY(M)]

BYTES or STRING

n/a
Either the raw bytes (the default), a base64-encoded String, or a base64-url-safe-encoded String, or a hex-encoded String, based on the binary.handling.mode connector configuration property setting.

TINYBLOB

BYTES or STRING

n/a
Either the raw bytes (the default), a base64-encoded String, or a base64-url-safe-encoded String, or a hex-encoded String, based on the binary.handling.mode connector configuration property setting.

TINYTEXT

STRING

n/a

BLOB

BYTES or STRING

n/a
Either the raw bytes (the default), a base64-encoded String, or a base64-url-safe-encoded String, or a hex-encoded String, based on the binary.handling.mode connector configuration property setting.
Only values with a size of up to 2GB are supported. It is recommended to externalize large column values, using the claim check pattern.

TEXT

STRING

n/a
Only values with a size of up to 2GB are supported. It is recommended to externalize large column values, using the claim check pattern.

MEDIUMBLOB

BYTES or STRING

n/a
Either the raw bytes (the default), a base64-encoded String, or a base64-url-safe-encoded String, or a hex-encoded String, based on the binary.handling.mode connector configuration property setting.

MEDIUMTEXT

STRING

n/a

LONGBLOB

BYTES or STRING

n/a
Either the raw bytes (the default), a base64-encoded String, or a base64-url-safe-encoded String, or a hex-encoded String, based on the binary.handling.mode connector configuration property setting.
Only values with a size of up to 2GB are supported. It is recommended to externalize large column values, using the claim check pattern.

LONGTEXT

STRING

n/a
Only values with a size of up to 2GB are supported. It is recommended to externalize large column values, using the claim check pattern.

JSON

STRING

io.debezium.data.Json
Contains the string representation of a JSON document, array, or scalar.

ENUM

STRING

io.debezium.data.Enum
The allowed schema parameter contains the comma-separated list of allowed values.

SET

STRING

io.debezium.data.EnumSet
The allowed schema parameter contains the comma-separated list of allowed values.

YEAR[(2|4)]

INT32

io.debezium.time.Year

TIMESTAMP[(M)]

STRING

io.debezium.time.ZonedTimestamp
In ISO 8601 format with microsecond precision. MySQL allows M to be in the range of 0-6.

Temporal types

Excluding the TIMESTAMP data type, MySQL temporal types depend on the value of the time.precision.mode connector configuration property. For TIMESTAMP columns whose default value is specified as CURRENT_TIMESTAMP or NOW, the value 1970-01-01 00:00:00 is used as the default value in the Kafka Connect schema.

MySQL allows zero-values for DATE, DATETIME, and TIMESTAMP columns because zero-values are sometimes preferred over null values. The MySQL connector represents zero-values as null values when the column definition allows null values, or as the epoch day when the column does not allow null values.

Temporal values without time zones

The DATETIME type represents a local date and time such as “2018-01-13 09:48:27”. As you can see, there is no time zone information. Such columns are converted into epoch milliseconds or microseconds based on the column’s precision by using UTC. The TIMESTAMP type represents a timestamp without time zone information. It is converted by MySQL from the server (or session’s) current time zone into UTC when writing and from UTC into the server (or session’s) current time zone when reading back the value. For example:

  • DATETIME with a value of 2018-06-20 06:37:03 becomes 1529476623000.

  • TIMESTAMP with a value of 2018-06-20 06:37:03 becomes 2018-06-20T13:37:03Z.

Such columns are converted into an equivalent io.debezium.time.ZonedTimestamp in UTC based on the server (or session’s) current time zone. The time zone will be queried from the server by default. If this fails, it must be specified explicitly by the database connectionTimeZone MySQL configuration option. For example, if the database’s time zone (either globally or configured for the connector by means of the connectionTimeZone option) is “America/Los_Angeles”, the TIMESTAMP value “2018-06-20 06:37:03” is represented by a ZonedTimestamp with the value “2018-06-20T13:37:03Z”.

The time zone of the JVM running Kafka Connect and Debezium does not affect these conversions.

More details about properties related to temporal values are in the documentation for MySQL connector configuration properties.

time.precision.mode=adaptive_time_microseconds(default)

The MySQL connector determines the literal type and semantic type based on the column’s data type definition so that events represent exactly the values in the database. All time fields are in microseconds. Only positive TIME field values in the range of 00:00:00.000000 to 23:59:59.999999 can be captured correctly.

Table 14. Mappings when time.precision.mode=adaptive_time_microseconds
MySQL typeLiteral typeSemantic type

DATE

INT32

io.debezium.time.Date
Represents the number of days since the epoch.

TIME[(M)]

INT64

io.debezium.time.MicroTime
Represents the time value in microseconds and does not include time zone information. MySQL allows M to be in the range of 0-6.

DATETIME, DATETIME(0), DATETIME(1), DATETIME(2), DATETIME(3)

INT64

io.debezium.time.Timestamp
Represents the number of milliseconds past the epoch and does not include time zone information.

DATETIME(4), DATETIME(5), DATETIME(6)

INT64

io.debezium.time.MicroTimestamp
Represents the number of microseconds past the epoch and does not include time zone information.

time.precision.mode=connect

The MySQL connector uses defined Kafka Connect logical types. This approach is less precise than the default approach and the events could be less precise if the database column has a fractional second precision value of greater than 3. Values in only the range of 00:00:00.000 to 23:59:59.999 can be handled. Set time.precision.mode=connect only if you can ensure that the TIME values in your tables never exceed the supported ranges. The connect setting is expected to be removed in a future version of Debezium.

Table 15. Mappings when time.precision.mode=connect
MySQL typeLiteral typeSemantic type

DATE

INT32

org.apache.kafka.connect.data.Date
Represents the number of days since the epoch.

TIME[(M)]

INT64

org.apache.kafka.connect.data.Time
Represents the time value in microseconds since midnight and does not include time zone information.

DATETIME[(M)]

INT64

org.apache.kafka.connect.data.Timestamp
Represents the number of milliseconds since the epoch, and does not include time zone information.

Decimal types

Debezium connectors handle decimals according to the setting of the decimal.handling.mode connector configuration property.

decimal.handling.mode=precise

Table 16. Mappings when decimal.handling.mode=precise
MySQL typeLiteral typeSemantic type

NUMERIC[(M[,D])]

BYTES

org.apache.kafka.connect.data.Decimal
The scale schema parameter contains an integer that represents how many digits the decimal point shifted.

DECIMAL[(M[,D])]

BYTES

org.apache.kafka.connect.data.Decimal
The scale schema parameter contains an integer that represents how many digits the decimal point shifted.

decimal.handling.mode=double

Table 17. Mappings when decimal.handling.mode=double
MySQL typeLiteral typeSemantic type

NUMERIC[(M[,D])]

FLOAT64

n/a

DECIMAL[(M[,D])]

FLOAT64

n/a

decimal.handling.mode=string

Table 18. Mappings when decimal.handling.mode=string
MySQL typeLiteral typeSemantic type

NUMERIC[(M[,D])]

STRING

n/a

DECIMAL[(M[,D])]

STRING

n/a

Boolean values

MySQL handles the BOOLEAN value internally in a specific way. The BOOLEAN column is internally mapped to the TINYINT(1) data type. When the table is created during streaming then it uses proper BOOLEAN mapping as Debezium receives the original DDL. During snapshots, Debezium executes SHOW CREATE TABLE to obtain table definitions that return TINYINT(1) for both BOOLEAN and TINYINT(1) columns. Debezium then has no way to obtain the original type mapping and so maps to TINYINT(1).

To enable you to convert source columns to Boolean data types, Debezium provides a TinyIntOneToBooleanConverter custom converter that you can use in one of the following ways:

  • Map all TINYINT(1) or TINYINT(1) UNSIGNED columns to BOOLEAN types.

  • Enumerate a subset of columns by using a comma-separated list of regular expressions.
    To use this type of conversion, you must set the converters configuration property with the selector parameter, as shown in the following example:

    1. converters=boolean
    2. boolean.type=io.debezium.connector.mysql.converters.TinyIntOneToBooleanConverter
    3. boolean.selector=db1.table1.*, db1.table2.column1
  • NOTE: MySQL8 not showing the length of tinyint unsigned type when snapshot executes SHOW CREATE TABLE, which means this converter doesn’t work. The new option length.checker can solve this issue, the default value is true. Disable the length.checker and specify the columns that need to be converted to selector property instead of converting all columns based on type, as shown in the following example:

    1. converters=boolean
    2. boolean.type=io.debezium.connector.mysql.converters.TinyIntOneToBooleanConverter
    3. boolean.length.checker=false
    4. boolean.selector=db1.table1.*, db1.table2.column1

Spatial types

Currently, the Debezium MySQL connector supports the following spatial data types.

Table 19. Description of spatial type mappings
MySQL typeLiteral typeSemantic type

GEOMETRY,
LINESTRING,
POLYGON,
MULTIPOINT,
MULTILINESTRING,
MULTIPOLYGON,
GEOMETRYCOLLECTION

STRUCT

io.debezium.data.geometry.Geometry
Contains a structure with two fields:

  • srid (INT32: spatial reference system ID that defines the type of geometry object stored in the structure

  • wkb (BYTES): binary representation of the geometry object encoded in the Well-Known-Binary (wkb) format. See the Open Geospatial Consortium for more details.

Setting up MySQL

Some MySQL setup tasks are required before you can install and run a Debezium connector.

Creating a user

A Debezium MySQL connector requires a MySQL user account. This MySQL user must have appropriate permissions on all databases for which the Debezium MySQL connector captures changes.

Prerequisites

  • A MySQL server.

  • Basic knowledge of SQL commands.

Procedure

  1. Create the MySQL user:

    1. mysql> CREATE USER 'user'@'localhost' IDENTIFIED BY 'password';
  2. Grant the required permissions to the user:

    1. mysql> GRANT SELECT, RELOAD, SHOW DATABASES, REPLICATION SLAVE, REPLICATION CLIENT ON *.* TO 'user' IDENTIFIED BY 'password';

    The table below describes the permissions.

    If using a hosted option such as Amazon RDS or Amazon Aurora that does not allow a global read lock, table-level locks are used to create the consistent snapshot. In this case, you need to also grant LOCK TABLES permissions to the user that you create. See snapshots for more details.
  3. Finalize the user’s permissions:

    1. mysql> FLUSH PRIVILEGES;
Table 20. Descriptions of user permissions
KeywordDescription

SELECT

Enables the connector to select rows from tables in databases. This is used only when performing a snapshot.

RELOAD

Enables the connector the use of the FLUSH statement to clear or reload internal caches, flush tables, or acquire locks. This is used only when performing a snapshot.

SHOW DATABASES

Enables the connector to see database names by issuing the SHOW DATABASE statement. This is used only when performing a snapshot.

REPLICATION SLAVE

Enables the connector to connect to and read the MySQL server binlog.

REPLICATION CLIENT

Enables the connector the use of the following statements:

  • SHOW MASTER STATUS

  • SHOW SLAVE STATUS

  • SHOW BINARY LOGS

The connector always requires this.

ON

Identifies the database to which the permissions apply.

TO ‘user’

Specifies the user to grant the permissions to.

IDENTIFIED BY ‘password’

Specifies the user’s MySQL password.

Enabling the binlog

You must enable binary logging for MySQL replication. The binary logs record transaction updates for replication tools to propagate changes.

Prerequisites

  • A MySQL server.

  • Appropriate MySQL user privileges.

Procedure

  1. Check whether the log-bin option is already on:

    1. // for MySql 5.x
    2. mysql> SELECT variable_value as "BINARY LOGGING STATUS (log-bin) ::"
    3. FROM information_schema.global_variables WHERE variable_name='log_bin';
    4. // for MySql 8.x
    5. mysql> SELECT variable_value as "BINARY LOGGING STATUS (log-bin) ::"
    6. FROM performance_schema.global_variables WHERE variable_name='log_bin';
  2. If it is OFF, configure your MySQL server configuration file with the following properties, which are described in the table below:

    1. server-id = 223344 # Querying variable is called server_id, e.g. SELECT variable_value FROM information_schema.global_variables WHERE variable_name='server_id';
    2. log_bin = mysql-bin
    3. binlog_format = ROW
    4. binlog_row_image = FULL
    5. binlog_expire_logs_seconds = 864000
  3. Confirm your changes by checking the binlog status once more:

    1. // for MySql 5.x
    2. mysql> SELECT variable_value as "BINARY LOGGING STATUS (log-bin) ::"
    3. FROM information_schema.global_variables WHERE variable_name='log_bin';
    4. // for MySql 8.x
    5. mysql> SELECT variable_value as "BINARY LOGGING STATUS (log-bin) ::"
    6. FROM performance_schema.global_variables WHERE variable_name='log_bin';
  4. If you run MySQL on Amazon RDS, you must enable automated backups for your database instance for binary logging to occur. If the database instance is not configured to perform automated backups, the binlog is disabled, even if you apply the settings described in the previous steps.

Table 21. Descriptions of MySQL binlog configuration properties
PropertyDescription

server-id

The value for the server-id must be unique for each server and replication client in the MySQL cluster. During MySQL connector set up, Debezium assigns a unique server ID to the connector.

log_bin

The value of log_bin is the base name of the sequence of binlog files.

binlog_format

The binlog-format must be set to ROW or row.

binlog_row_image

The binlog_row_image must be set to FULL or full.

binlog_expire_logs_seconds

The binlog_expire_logs_seconds corresponds to deprecated system variable expire_logs_days. This is the number of seconds for automatic binlog file removal. The default is 2592000, which equals 30 days. Set the value to match the needs of your environment. See MySQL purges binlog files.

Enabling GTIDs

Global transaction identifiers (GTIDs) uniquely identify transactions that occur on a server within a cluster. Though not required for a Debezium MySQL connector, using GTIDs simplifies replication and enables you to more easily confirm if primary and replica servers are consistent.

GTIDs are available in MySQL 5.6.5 and later. See the MySQL documentation for more details.

Prerequisites

  • A MySQL server.

  • Basic knowledge of SQL commands.

  • Access to the MySQL configuration file.

Procedure

  1. Enable gtid_mode:

    1. mysql> gtid_mode=ON
  2. Enable enforce_gtid_consistency:

    1. mysql> enforce_gtid_consistency=ON
  3. Confirm the changes:

    1. mysql> show global variables like '%GTID%';

Result

  1. +--------------------------+-------+
  2. | Variable_name | Value |
  3. +--------------------------+-------+
  4. | enforce_gtid_consistency | ON |
  5. | gtid_mode | ON |
  6. +--------------------------+-------+
Table 22. Descriptions of GTID options
OptionDescription

gtid_mode

Boolean that specifies whether GTID mode of the MySQL server is enabled or not.

  • ON = enabled

  • OFF = disabled

enforce_gtid_consistency

Boolean that specifies whether the server enforces GTID consistency by allowing the execution of statements that can be logged in a transactionally safe manner. Required when using GTIDs.

  • ON = enabled

  • OFF = disabled

Configuring session timeouts

When an initial consistent snapshot is made for large databases, your established connection could timeout while the tables are being read. You can prevent this behavior by configuring interactive_timeout and wait_timeout in your MySQL configuration file.

Prerequisites

  • A MySQL server.

  • Basic knowledge of SQL commands.

  • Access to the MySQL configuration file.

Procedure

  1. Configure interactive_timeout:

    1. mysql> interactive_timeout=<duration-in-seconds>
  2. Configure wait_timeout:

    1. mysql> wait_timeout=<duration-in-seconds>
Table 23. Descriptions of MySQL session timeout options
OptionDescription

interactive_timeout

The number of seconds the server waits for activity on an interactive connection before closing it. See MySQL’s documentation for more details.

wait_timeout

The number of seconds the server waits for activity on a non-interactive connection before closing it. See MySQL’s documentation for more details.

Enabling query log events

You might want to see the original SQL statement for each binlog event. Enabling the binlog_rows_query_log_events option in the MySQL configuration or binlog_annotate_row_events in the MariaDB configuration file allows you to do this.

This option is available in MySQL 5.6 and later.

Prerequisites

  • A MySQL server.

  • Basic knowledge of SQL commands.

  • Access to the MySQL configuration file.

Procedure

  • Enable binlog_rows_query_log_events in MySQL or binlog_annotate_row_events in MariaDB:

    1. mysql> binlog_rows_query_log_events=ON
    1. mariadb> binlog_annotate_row_events=ON

    binlog_rows_query_log_events or binlog_annotate_row_events is set to a value that enables/disables support for including the original SQL statement in the binlog entry.

    • ON = enabled

    • OFF = disabled

Validating binlog row value options

Check binlog_row_value_options variable, and make sure that value is not set to PARTIAL_JSON, since in such case connector might fail to consume UPDATE events.

Prerequisites

  • A MySQL server.

  • Basic knowledge of SQL commands.

  • Access to the MySQL configuration file.

Procedure

  1. Check current variable value

    1. mysql> show global variables where variable_name = 'binlog_row_value_options';
  2. Result

    1. +--------------------------+-------+
    2. | Variable_name | Value |
    3. +--------------------------+-------+
    4. | binlog_row_value_options | |
    5. +--------------------------+-------+
  3. In case value is PARTIAL_JSON, unset this variable by:

    1. mysql> set @@global.binlog_row_value_options="" ;

Deployment

To deploy a Debezium MySQL connector, you install the Debezium MySQL connector archive, configure the connector, and start the connector by adding its configuration to Kafka Connect.

Prerequisites

Procedure

  1. Download the Debezium MySQL connector plug-in.

  2. Extract the files into your Kafka Connect environment.

  3. Add the directory with the JAR files to Kafka Connect’s plugin.path.

  4. Configure the connector and add the configuration to your Kafka Connect cluster.

  5. Restart your Kafka Connect process to pick up the new JAR files.

If you are working with immutable containers, see Debezium’s Container images for Apache Zookeeper, Apache Kafka, MySQL, and Kafka Connect with the MySQL connector already installed and ready to run.

You can also run Debezium on Kubernetes and OpenShift.

MySQL connector configuration example

Following is an example of the configuration for a connector instance that captures data from a MySQL server on port 3306 at 192.168.99.100, which we logically name fullfillment. Typically, you configure the Debezium MySQL connector in a JSON file by setting the configuration properties that are available for the connector.

You can choose to produce events for a subset of the schemas and tables in a database. Optionally, you can ignore, mask, or truncate columns that contain sensitive data, that are larger than a specified size, or that you do not need.

  1. {
  2. "name": "inventory-connector", (1)
  3. "config": {
  4. "connector.class": "io.debezium.connector.mysql.MySqlConnector", (2)
  5. "database.hostname": "192.168.99.100", (3)
  6. "database.port": "3306", (4)
  7. "database.user": "debezium-user", (5)
  8. "database.password": "debezium-user-pw", (6)
  9. "database.server.id": "184054", (7)
  10. "topic.prefix": "fullfillment", (8)
  11. "database.include.list": "inventory", (9)
  12. "schema.history.internal.kafka.bootstrap.servers": "kafka:9092", (10)
  13. "schema.history.internal.kafka.topic": "schemahistory.fullfillment", (11)
  14. "include.schema.changes": "true" (12)
  15. }
  16. }
1Connector’s name when registered with the Kafka Connect service.
2Connector’s class name.
3MySQL server address.
4MySQL server port number.
5MySQL user with the appropriate privileges.
6MySQL user’s password.
7Unique ID of the connector.
8Topic prefix for the MySQL server or cluster.
9List of databases hosted by the specified server.
10List of Kafka brokers that the connector uses to write and recover DDL statements to the database schema history topic.
11Name of the database schema history topic. This topic is for internal use only and should not be used by consumers.
12Flag that specifies if the connector should generate events for DDL changes and emit them to the fulfillment schema change topic for use by consumers.

For the complete list of the configuration properties that you can set for the Debezium MySQL connector, see MySQL connector configuration properties.

You can send this configuration with a POST command to a running Kafka Connect service. The service records the configuration and starts one connector task that performs the following actions:

  • Connects to the MySQL database.

  • Reads change-data tables for tables in capture mode.

  • Streams change event records to Kafka topics.

Adding connector configuration

To start running a MySQL connector, configure a connector configuration, and add the configuration to your Kafka Connect cluster.

Prerequisites

Procedure

  1. Create a configuration for the MySQL connector.

  2. Use the Kafka Connect REST API to add that connector configuration to your Kafka Connect cluster.

Results

After the connector starts, it performs a consistent snapshot of the MySQL databases that the connector is configured for. The connector then starts generating data change events for row-level operations and streaming change event records to Kafka topics.

Connector properties

The Debezium MySQL connector has numerous configuration properties that you can use to achieve the right connector behavior for your application. Many properties have default values. Information about the properties is organized as follows:

The following configuration properties are required unless a default value is available.

Required Debezium MySQL connector configuration properties

PropertyDefaultDescription

No default

Unique name for the connector. Attempting to register again with the same name fails. This property is required by all Kafka Connect connectors.

No default

The name of the Java class for the connector. Always specify io.debezium.connector.mysql.MySqlConnector for the MySQL connector.

1

The maximum number of tasks that should be created for this connector. The MySQL connector always uses a single task and therefore does not use this value, so the default is always acceptable.

mysql

The connector adapter mode to be used. For information about how to connect Debezium to MariaDB, see Using the connector with a MariaDB database.

jdbc:mysql

JDBC protocol used by the driver connection string for connecting to the database. For information about how to connect Debezium to MariaDB, see Using the connector with a MariaDB database.

com.mysql.cj.jdbc.Driver

The driver class name to use. This can be useful when using an alternative driver to the one packaged with the connector. For information about how to connect Debezium to MariaDB, see Using the connector with a MariaDB database.

No default

IP address or host name of the MySQL database server.

3306

Integer port number of the MySQL database server.

No default

Name of the MySQL user to use when connecting to the MySQL database server.

No default

Password to use when connecting to the MySQL database server.

No default

Topic prefix that provides a namespace for the particular MySQL database server/cluster in which Debezium is capturing changes. The topic prefix should be unique across all other connectors, since it is used as a prefix for all Kafka topic names that receive events emitted by this connector. Only alphanumeric characters, hyphens, dots and underscores must be used in the database server logical name.

Do not change the value of this property. If you change the name value, after a restart, instead of continuing to emit events to the original topics, the connector emits subsequent events to topics whose names are based on the new value. The connector is also unable to recover its database schema history topic.

No default

A numeric ID of this database client, which must be unique across all currently-running database processes in the MySQL cluster. This connector joins the MySQL database cluster as another server (with this unique ID) so it can read the binlog.

empty string

An optional, comma-separated list of regular expressions that match the names of the databases for which to capture changes. The connector does not capture changes in any database whose name is not in database.include.list. By default, the connector captures changes in all databases.

To match the name of a database, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the database; it does not match substrings that might be present in a database name.
If you include this property in the configuration, do not also set the database.exclude.list property.

empty string

An optional, comma-separated list of regular expressions that match the names of databases for which you do not want to capture changes. The connector captures changes in any database whose name is not in the database.exclude.list.

To match the name of a database, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the database; it does not match substrings that might be present in a database name.
If you include this property in the configuration, do not also set the database.include.list property.

empty string

An optional, comma-separated list of regular expressions that match fully-qualified table identifiers of tables whose changes you want to capture. The connector does not capture changes in any table that is not included in table.include.list. Each identifier is of the form databaseName.tableName. By default, the connector captures changes in every non-system table in each database whose changes are being captured.

To match the name of a table, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the table; it does not match substrings that might be present in a table name.
If you include this property in the configuration, do not also set the table.exclude.list property.

empty string

An optional, comma-separated list of regular expressions that match fully-qualified table identifiers for tables whose changes you do not want to capture. The connector captures changes in any table that is not included in table.exclude.list. Each identifier is of the form databaseName.tableName.

To match the name of a column, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the table; it does not match substrings that might be present in a table name.
If you include this property in the configuration, do not also set the table.include.list property.

empty string

An optional, comma-separated list of regular expressions that match the fully-qualified names of columns to exclude from change event record values. Fully-qualified names for columns are of the form databaseName.tableName.columnName.

To match the name of a column, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the column; it does not match substrings that might be present in a column name. If you include this property in the configuration, do not also set the column.include.list property.

empty string

An optional, comma-separated list of regular expressions that match the fully-qualified names of columns to include in change event record values. Fully-qualified names for columns are of the form databaseName.tableName.columnName.

To match the name of a column, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the column; it does not match substrings that might be present in a column name.
If you include this property in the configuration, do not set the column.exclude.list property.

false

Specifies whether to skip publishing messages when there is no change in included columns. This would essentially filter messages if there is no change in columns included as per column.include.list or column.exclude.list properties.

n/a

An optional, comma-separated list of regular expressions that match the fully-qualified names of character-based columns. Set this property if you want to truncate the data in a set of columns when it exceeds the number of characters specified by the length in the property name. Set length to a positive integer value, for example, column.truncate.to.20.chars.

The fully-qualified name of a column observes the following format: databaseName.tableName.columnName. To match the name of a column, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the column; the expression does not match substrings that might be present in a column name.

You can specify multiple properties with different lengths in a single configuration.

n/a

An optional, comma-separated list of regular expressions that match the fully-qualified names of character-based columns. Set this property if you want the connector to mask the values for a set of columns, for example, if they contain sensitive data. Set length to a positive integer to replace data in the specified columns with the number of asterisk () characters specified by the length in the property name. Set length to 0 (zero) to replace data in the specified columns with an empty string.

The fully-qualified name of a column observes the following format: databaseName.tableName.columnName. To match the name of a column, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the column; the expression does not match substrings that might be present in a column name.

You can specify multiple properties with different lengths in a single configuration.

n/a

An optional, comma-separated list of regular expressions that match the fully-qualified names of character-based columns. Fully-qualified names for columns are of the form <databaseName>.<tableName>.<columnName>.
To match the name of a column Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the column; the expression does not match substrings that might be present in a column name. In the resulting change event record, the values for the specified columns are replaced with pseudonyms.

A pseudonym consists of the hashed value that results from applying the specified hashAlgorithm and salt. Based on the hash function that is used, referential integrity is maintained, while column values are replaced with pseudonyms. Supported hash functions are described in the MessageDigest section of the Java Cryptography Architecture Standard Algorithm Name Documentation.

In the following example, CzQMA0cB5K is a randomly selected salt.

  1. column.mask.hash.SHA-256.with.salt.CzQMA0cB5K = inventory.orders.customerName, inventory.shipment.customerName

If necessary, the pseudonym is automatically shortened to the length of the column. The connector configuration can include multiple properties that specify different hash algorithms and salts.

Depending on the hashAlgorithm used, the salt selected, and the actual data set, the resulting data set might not be completely masked.

Hashing strategy version 2 should be used to ensure fidelity if the value is being hashed in different places or systems.

n/a

An optional, comma-separated list of regular expressions that match the fully-qualified names of columns for which you want the connector to emit extra parameters that represent column metadata. When this property is set, the connector adds the following fields to the schema of event records:

  • debezium.source.column.type

  • debezium.source.column.length

  • debezium.source.column.scale

These parameters propagate a column’s original type name and length (for variable-width types), respectively.
Enabling the connector to emit this extra data can assist in properly sizing specific numeric or character-based columns in sink databases.

The fully-qualified name of a column observes one of the following formats: databaseName.tableName.columnName, or databaseName.schemaName.tableName.columnName.
To match the name of a column, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the column; the expression does not match substrings that might be present in a column name.

n/a

An optional, comma-separated list of regular expressions that specify the fully-qualified names of data types that are defined for columns in a database. When this property is set, for columns with matching data types, the connector emits event records that include the following extra fields in their schema:

  • debezium.source.column.type

  • debezium.source.column.length

  • debezium.source.column.scale

These parameters propagate a column’s original type name and length (for variable-width types), respectively.
Enabling the connector to emit this extra data can assist in properly sizing specific numeric or character-based columns in sink databases.

The fully-qualified name of a column observes one of the following formats: databaseName.tableName.typeName, or databaseName.schemaName.tableName.typeName.
To match the name of a data type, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the data type; the expression does not match substrings that might be present in a type name.

For the list of MySQL-specific data type names, see the MySQL data type mappings.

adaptive_time_microseconds

Time, date, and timestamps can be represented with different kinds of precision, including:

adaptive_time_microseconds (the default) captures the date, datetime and timestamp values exactly as in the database using either millisecond, microsecond, or nanosecond precision values based on the database column’s type, with the exception of TIME type fields, which are always captured as microseconds.

adaptive (deprecated) captures the time and timestamp values exactly as in the database using either millisecond, microsecond, or nanosecond precision values based on the database column’s type.

connect always represents time and timestamp values using Kafka Connect’s built-in representations for Time, Date, and Timestamp, which use millisecond precision regardless of the database columns’ precision.

precise

Specifies how the connector should handle values for DECIMAL and NUMERIC columns:

precise (the default) represents them precisely using java.math.BigDecimal values represented in change events in a binary form.

double represents them using double values, which may result in a loss of precision but is easier to use.

string encodes values as formatted strings, which is easy to consume but semantic information about the real type is lost.

long

Specifies how BIGINT UNSIGNED columns should be represented in change events. Possible settings are:

long represents values by using Java’s long, which might not offer the precision but which is easy to use in consumers. long is usually the preferred setting.

precise uses java.math.BigDecimal to represent values, which are encoded in the change events by using a binary representation and Kafka Connect’s org.apache.kafka.connect.data.Decimal type. Use this setting when working with values larger than 2^63, because these values cannot be conveyed by using long.

true

Boolean value that specifies whether the connector should publish changes in the database schema to a Kafka topic with the same name as the database server ID. Each schema change is recorded by using a key that contains the database name and whose value includes the DDL statement(s). This is independent of how the connector internally records database schema history.

false

Boolean value that specifies whether the connector should parse and publish table and column comments on metadata objects. Enabling this option will bring the implications on memory usage. The number and size of logical schema objects is what largely impacts how much memory is consumed by the Debezium connectors, and adding potentially large string data to each of them can potentially be quite expensive.

false

Boolean value that specifies whether the connector should include the original SQL query that generated the change event.

If you set this option to true then you must also configure MySQL with the binlog_rows_query_log_events option or MariaDB with the binlog_annotate_row_events option set to ON. When include.query is true, the query is not present for events that the snapshot process generates.
Setting include.query to true might expose tables or fields that are explicitly excluded or masked by including the original SQL statement in the change event. For this reason, the default setting is false.

For more information about configuring the database to return the original SQL statement for each log event, see Enabling query log events.

fail

Specifies how the connector should react to exceptions during deserialization of binlog events. This option is deprecated, please use event.processing.failure.handling.mode option instead.

fail propagates the exception, which indicates the problematic event and its binlog offset, and causes the connector to stop.

warn logs the problematic event and its binlog offset and then skips the event.

ignore passes over the problematic event and does not log anything.

fail

Specifies how the connector should react to binlog events that relate to tables that are not present in internal schema representation. That is, the internal representation is not consistent with the database.

fail throws an exception that indicates the problematic event and its binlog offset, and causes the connector to stop.

warn logs the problematic event and its binlog offset and skips the event.

skip passes over the problematic event and does not log anything.

30000

A positive integer value that specifies the maximum time in milliseconds this connector should wait after trying to connect to the MySQL database server before timing out. Defaults to 30 seconds.

No default

A comma-separated list of regular expressions that match source UUIDs in the GTID set used that the connector uses to find the binlog position on the MySQL server. When this property is set, the connector uses only the GTID ranges that have source UUIDs that match one of the specified include patterns.

To match the value of a GTID, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire UUID string; it does not match substrings that might be present in the UUID.
If you include this property in the configuration, do not also set the gtid.source.excludes property.

No default

A comma-separated list of regular expressions that match source UUIDs in the GTID set that the connector uses to find the binlog position on the MySQL server. When this property is set, the connector uses only the GTID ranges that have source UUIDs that do not match any of the specified exclude patterns.

To match the value of a GTID, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire UUID string; it does not match substrings that might be present in the UUID.
If you include this property in the configuration, do not also set the gtid.source.includes property.

true

Controls whether a delete event is followed by a tombstone event.

true - a delete operation is represented by a delete event and a subsequent tombstone event.

false - only a delete event is emitted.

After a source record is deleted, emitting a tombstone event (the default behavior) allows Kafka to completely delete all events that pertain to the key of the deleted row in case log compaction is enabled for the topic.

n/a

A list of expressions that specify the columns that the connector uses to form custom message keys for change event records that it publishes to the Kafka topics for specified tables.

By default, Debezium uses the primary key column of a table as the message key for records that it emits. In place of the default, or to specify a key for tables that lack a primary key, you can configure custom message keys based on one or more columns.

To establish a custom message key for a table, list the table, followed by the columns to use as the message key. Each list entry takes the following format:

<fully-qualified_tableName>:<keyColumn>,<keyColumn>

To base a table key on multiple column names, insert commas between the column names.

Each fully-qualified table name is a regular expression in the following format:

<databaseName>.<tableName>

The property can include entries for multiple tables. Use a semicolon to separate table entries in the list.

The following example sets the message key for the tables inventory.customers and purchase.orders:

inventory.customers:pk1,pk2;(.).purchaseorders:pk3,pk4

For the table inventory.customer, the columns pk1 and pk2 are specified as the message key. For the purchaseorders tables in any database, the columns pk3 and pk4 server as the message key.

There is no limit to the number of columns that you use to create custom message keys. However, it’s best to use the minimum number that are required to specify a unique key.

bytes

Specifies how binary columns, for example, blob, binary, varbinary, should be represented in change events. Possible settings:

bytes represents binary data as a byte array.

base64 represents binary data as a base64-encoded String.

base64-url-safe represents binary data as a base64-url-safe-encoded String.

hex represents binary data as a hex-encoded (base16) String.

none

Specifies how schema names should be adjusted for compatibility with the message converter used by the connector. Possible settings:

  • none does not apply any adjustment.

  • avro replaces the characters that cannot be used in the Avro type name with underscore.

  • avrounicode replaces the underscore or characters that cannot be used in the Avro type name with corresponding unicode like _uxxxx. Note: is an escape sequence like backslash in Java

none

Specifies how field names should be adjusted for compatibility with the message converter used by the connector. Possible settings:

  • none does not apply any adjustment.

  • avro replaces the characters that cannot be used in the Avro type name with underscore.

  • avrounicode replaces the underscore or characters that cannot be used in the Avro type name with corresponding unicode like _uxxxx. Note: is an escape sequence like backslash in Java

See Avro naming for more details.

Advanced MySQL connector configuration properties

The following table describes advanced MySQL connector properties. The default values for these properties rarely need to be changed. Therefore, you do not need to specify them in the connector configuration.

Table 24. Descriptions of MySQL connector advanced configuration properties
PropertyDefaultDescription

true

A Boolean value that specifies whether a separate thread should be used to ensure that the connection to the MySQL server/cluster is kept alive.

No default

Enumerates a comma-separated list of the symbolic names of the custom converter instances that the connector can use.
For example, boolean.
This property is required to enable the connector to use a custom converter.

For each converter that you configure for a connector, you must also add a .type property, which specifies the fully-qualified name of the class that implements the converter interface. The .type property uses the following format:

<converterSymbolicName>.type

For example,

  1. boolean.type: io.debezium.connector.mysql.converters.TinyIntOneToBooleanConverter

If you want to further control the behavior of a configured converter, you can add one or more configuration parameters to pass values to the converter. To associate these additional configuration parameter with a converter, prefix the paraemeter name with the symbolic name of the converter.

For example, to define a selector parameter that specifies the subset of columns that the boolean converter processes, add the following property:

  1. boolean.selector=db1.table1., db1.table2.column1

true

A Boolean value that specifies whether built-in system tables should be ignored. This applies regardless of the table include and exclude lists. By default, system tables are excluded from having their changes captured, and no events are generated when changes are made to any system tables.

preferred

Specifies whether to use an encrypted connection. Possible settings are:

disabled specifies the use of an unencrypted connection.

preferred establishes an encrypted connection if the server supports secure connections. If the server does not support secure connections, falls back to an unencrypted connection.

required establishes an encrypted connection or fails if one cannot be made for any reason.

verify_ca behaves like required but additionally it verifies the server TLS certificate against the configured Certificate Authority (CA) certificates and fails if the server TLS certificate does not match any valid CA certificates.

verify_identity behaves like verify_ca but additionally verifies that the server certificate matches the host of the remote connection.

No defaults

The location of the key store file. This is optional and can be used for two-way authentication between the client and the MySQL Server.

No defaults

The password for the key store file. This is optional and only needed if database.ssl.keystore is configured.

No defaults

The location of the trust store file for the server certificate verification.

No defaults

The password for the trust store file. Used to check the integrity of the truststore, and unlock the truststore.

0

The size of a look-ahead buffer used by the binlog reader. The default setting of 0 disables buffering.

Under specific conditions, it is possible that the MySQL binlog contains uncommitted data finished by a ROLLBACK statement. Typical examples are using savepoints or mixing temporary and regular table changes in a single transaction.

When a beginning of a transaction is detected then Debezium tries to roll forward the binlog position and find either COMMIT or ROLLBACK so it can determine whether to stream the changes from the transaction. The size of the binlog buffer defines the maximum number of changes in the transaction that Debezium can buffer while searching for transaction boundaries. If the size of the transaction is larger than the buffer then Debezium must rewind and re-read the events that have not fit into the buffer while streaming.

NOTE: This feature is incubating. Feedback is encouraged. It is expected that this feature is not completely polished.

2048

Positive integer value that specifies the maximum size of each batch of events that should be processed during each iteration of this connector. Defaults to 2048.

8192

Positive integer value that specifies the maximum number of records that the blocking queue can hold. When Debezium reads events streamed from the database, it places the events in the blocking queue before it writes them to Kafka. The blocking queue can provide backpressure for reading change events from the database in cases where the connector ingests messages faster than it can write them to Kafka, or when Kafka becomes unavailable. Events that are held in the queue are disregarded when the connector periodically records offsets. Always set the value of max.queue.size to be larger than the value of max.batch.size.

0

A long integer value that specifies the maximum volume of the blocking queue in bytes. By default, volume limits are not specified for the blocking queue. To specify the number of bytes that the queue can consume, set this property to a positive long value.
If max.queue.size is also set, writing to the queue is blocked when the size of the queue reaches the limit specified by either property. For example, if you set max.queue.size=1000, and max.queue.size.in.bytes=5000, writing to the queue is blocked after the queue contains 1000 records, or after the volume of the records in the queue reaches 5000 bytes.

500

Positive integer value that specifies the number of milliseconds the connector should wait for new change events to appear before it starts processing a batch of events. Defaults to 500 milliseconds, or 0.5 second.

initial

Specifies the criteria for running a snapshot when the connector starts. Possible settings are:

initial - the connector runs a snapshot only when no offsets have been recorded for the logical server name.

initial_only - the connector runs a snapshot only when no offsets have been recorded for the logical server name and then stops; i.e. it will not read change events from the binlog.

when_needed - the connector runs a snapshot upon startup whenever it deems it necessary. That is, when no offsets are available, or when a previously recorded offset specifies a binlog location or GTID that is not available in the server.

never - the connector never uses snapshots. Upon first startup with a logical server name, the connector reads from the beginning of the binlog. Configure this behavior with care. It is valid only when the binlog is guaranteed to contain the entire history of the database.

schema_only - the connector runs a snapshot of the schemas and not the data. This setting is useful when you do not need the topics to contain a consistent snapshot of the data but need them to have only the changes since the connector was started.

schema_only_recovery - this is a recovery setting for a connector that has already been capturing changes. When you restart the connector, this setting enables recovery of a corrupted or lost database schema history topic. You might set it periodically to “clean up” a database schema history topic that has been growing unexpectedly. Database schema history topics require infinite retention.

minimal

Controls whether and how long the connector holds the global MySQL read lock, which prevents any updates to the database, while the connector is performing a snapshot. Possible settings are:

minimal - the connector holds the global read lock for only the initial portion of the snapshot during which the connector reads the database schemas and other metadata. The remaining work in a snapshot involves selecting all rows from each table. The connector can do this in a consistent fashion by using a REPEATABLE READ transaction. This is the case even when the global read lock is no longer held and other MySQL clients are updating the database.

minimal_percona - the connector holds the global backup lock for only the initial portion of the snapshot during which the connector reads the database schemas and other metadata. The remaining work in a snapshot involves selecting all rows from each table. The connector can do this in a consistent fashion by using a REPEATABLE READ transaction. This is the case even when the global backup lock is no longer held and other MySQL clients are updating the database. This mode does not flush tables to disk, is not blocked by long-running reads, and is available only in Percona Server.

extended - blocks all writes for the duration of the snapshot. Use this setting if there are clients that are submitting operations that MySQL excludes from REPEATABLE READ semantics.

none - prevents the connector from acquiring any table locks during the snapshot. While this setting is allowed with all snapshot modes, it is safe to use if and only if no schema changes are happening while the snapshot is running. For tables defined with MyISAM engine, the tables would still be locked despite this property being set as MyISAM acquires a table lock. This behavior is unlike InnoDB engine, which acquires row level locks.

All tables specified in table.include.list

An optional, comma-separated list of regular expressions that match the fully-qualified names (<databaseName>.<tableName>) of the tables to include in a snapshot. The specified items must be named in the connector’s table.include.list property. This property takes effect only if the connector’s snapshot.mode property is set to a value other than never.
This property does not affect the behavior of incremental snapshots.

To match the name of a table, Debezium applies the regular expression that you specify as an anchored regular expression. That is, the specified expression is matched against the entire name string of the table; it does not match substrings that might be present in a table name.

No default

Specifies the table rows to include in a snapshot. Use the property if you want a snapshot to include only a subset of the rows in a table. This property affects snapshots only. It does not apply to events that the connector reads from the log.

The property contains a comma-separated list of fully-qualified table names in the form <databaseName>.<tableName>. For example,

“snapshot.select.statement.overrides”: “inventory.products,customers.orders”

For each table in the list, add a further configuration property that specifies the SELECT statement for the connector to run on the table when it takes a snapshot. The specified SELECT statement determines the subset of table rows to include in the snapshot. Use the following format to specify the name of this SELECT statement property:

snapshot.select.statement.overrides.<databaseName>.<tableName>. For example, snapshot.select.statement.overrides.customers.orders.

Example:

From a customers.orders table that includes the soft-delete column, delete_flag, add the following properties if you want a snapshot to include only those records that are not soft-deleted:

  1. snapshot.select.statement.overrides”: customer.orders”,
  2. snapshot.select.statement.overrides.customer.orders”: SELECT FROM [customers].[orders] WHERE delete_flag = 0 ORDER BY id DESC

In the resulting snapshot, the connector includes only the records for which delete_flag = 0.

1000

During a snapshot, the connector queries each table for which the connector is configured to capture changes. The connector uses each query result to produce a read event that contains data for all rows in that table. This property determines whether the MySQL connector puts results for a table into memory, which is fast but requires large amounts of memory, or streams the results, which can be slower but work for very large tables. The setting of this property specifies the minimum number of rows a table must contain before the connector streams results.

To skip all table size checks and always stream all results during a snapshot, set this property to 0.

0

Controls how frequently the connector sends heartbeat messages to a Kafka topic. The default behavior is that the connector does not send heartbeat messages.

Heartbeat messages are useful for monitoring whether the connector is receiving change events from the database. Heartbeat messages might help decrease the number of change events that need to be re-sent when a connector restarts. To send heartbeat messages, set this property to a positive integer, which indicates the number of milliseconds between heartbeat messages.

No default

Specifies a query that the connector executes on the source database when the connector sends a heartbeat message.

For example, this can be used to periodically capture the state of the executed GTID set in the source database.

INSERT INTO gtid_history_table (select * from mysql.gtid_executed)

No default

A semicolon separated list of SQL statements to be executed when a JDBC connection, not the connection that is reading the transaction log, to the database is established. To specify a semicolon as a character in a SQL statement and not as a delimiter, use two semicolons, (;;).

The connector might establish JDBC connections at its own discretion, so this property is ony for configuring session parameters. It is not for executing DML statements.

No default

An interval in milliseconds that the connector should wait before performing a snapshot when the connector starts. If you are starting multiple connectors in a cluster, this property is useful for avoiding snapshot interruptions, which might cause re-balancing of connectors.

No default

During a snapshot, the connector reads table content in batches of rows. This property specifies the maximum number of rows in a batch.

10000

Positive integer that specifies the maximum amount of time (in milliseconds) to wait to obtain table locks when performing a snapshot. If the connector cannot acquire table locks in this time interval, the snapshot fails. See how MySQL connectors perform database snapshots.

true

Boolean value that indicates whether the connector converts a 2-digit year specification to 4 digits. Set to false when conversion is fully delegated to the database.

MySQL allows users to insert year values with either 2-digits or 4-digits. For 2-digit values, the value gets mapped to a year in the range 1970 - 2069. The default behavior is that the connector does the conversion.

v2

Schema version for the source block in Debezium events. Debezium 0.10 introduced a few breaking changes to the structure of the source block in order to unify the exposed structure across all the connectors.

By setting this option to v1, the structure used in earlier versions can be produced. However, this setting is not recommended and is planned for removal in a future Debezium version.

t

A comma-separated list of operation types that will be skipped during streaming. The operations include: c for inserts/create, u for updates, d for deletes, t for truncates, and none to not skip any operations. By default, truncate operations are skipped.

No default value

Fully-qualified name of the data collection that is used to send signals to the connector.
Use the following format to specify the collection name:
<databaseName>.<tableName>

source

List of the signaling channel names that are enabled for the connector. By default, the following channels are available:

No default

List of notification channel names that are enabled for the connector. By default, the following channels are available:

false

Allow schema changes during an incremental snapshot. When enabled the connector will detect schema change during an incremental snapshot and re-select a current chunk to avoid locking DDLs.

Note that changes to a primary key are not supported and can cause incorrect results if performed during an incremental snapshot. Another limitation is that if a schema change affects only columns’ default values, then the change won’t be detected until the DDL is processed from the binlog stream. This doesn’t affect the snapshot events’ values, but the schema of snapshot events may have outdated defaults.

1024

The maximum number of rows that the connector fetches and reads into memory during an incremental snapshot chunk. Increasing the chunk size provides greater efficiency, because the snapshot runs fewer snapshot queries of a greater size. However, larger chunk sizes also require more memory to buffer the snapshot data. Adjust the chunk size to a value that provides the best performance in your environment.

insert_insert

Specifies the watermarking mechanism that the connector uses during an incremental snapshot to deduplicate events that might be captured by an incremental snapshot and then recaptured after streaming resumes.
You can specify one of the following options:

    insert_insert

    When you send a signal to initiate an incremental snapshot, for every chunk that Debezium reads during the snapshot, it writes an entry to the signaling data collection to record the signal to open the snapshot window. After the snapshot completes, Debezium inserts a second entry that records the signal to close the window.

    insert_delete

    When you send a signal to initiate an incremental snapshot, for every chunk that Debezium reads, it writes a single entry to the signaling data collection to record the signal to open the snapshot window. After the snapshot completes, this entry is removed. No entry is created for the signal to close the snapshot window. Set this option to prevent rapid growth of the signaling data collection.

false

Switch to alternative incremental snapshot watermarks implementation to avoid writes to signal data collection

false

Determines whether the connector generates events with transaction boundaries and enriches change event envelopes with transaction metadata. Specify true if you want the connector to do this. See Transaction metadata for details.

fail

Specify how failures during processing of events (i.e. when encountering a corrupted event) should be handled. By default, fail mode raises an exception indicating the problematic event and its position, causing the connector to be stopped. warn mode does not raise the exception, instead the problematic event and its position will be logged and the event will be skipped. ignore mode ignores the problematic event completely with no logging.

io.debezium.schema.DefaultTopicNamingStrategy

The name of the TopicNamingStrategy class that should be used to determine the topic name for data change, schema change, transaction, heartbeat event etc., defaults to DefaultTopicNamingStrategy.

.

Specify the delimiter for topic name, defaults to ..

10000

The size used for holding the topic names in bounded concurrent hash map. This cache will help to determine the topic name corresponding to a given data collection.

debezium-heartbeat

Controls the name of the topic to which the connector sends heartbeat messages. The topic name has this pattern:

topic.heartbeat.prefix.topic.prefix

For example, if the topic prefix is fulfillment, the default topic name is debezium-heartbeat.fulfillment.

transaction

Controls the name of the topic to which the connector sends transaction metadata messages. The topic name has this pattern:

topic.prefix.topic.transaction

For example, if the topic prefix is fulfillment, the default topic name is fulfillment.transaction.

1

Specifies the number of threads that the connector uses when performing an initial snapshot. To enable parallel initial snapshots, set the property to a value greater than 1. In a parallel initial snapshot, the connector processes multiple tables concurrently. This feature is incubating.

disabled

Controls the order in which the connector processes tables when it performs an initial snapshot. Specify one of the following options:

    descending

    The connector snapshots tables in order, based on the number of rows from the highest to the lowest.

    ascending

    The connector snapshots tables in order, based on the number of rows, from lowest to highest.

    disabled

    The connector disregards row count when performing an initial snapshot.

No default

The custom metric tags will accept key-value pairs to customize the MBean object name which should be appended the end of regular name, each key would represent a tag for the MBean object name, and the corresponding value would be the value of that tag the key is. For example: k1=v1,k2=v2.

-1

The maximum number of retries on retriable errors (e.g. connection errors) before failing (-1 = no limit, 0 = disabled, > 0 = num of retries).

Debezium connector database schema history configuration properties

Debezium provides a set of schema.history.internal.* properties that control how the connector interacts with the schema history topic.

The following table describes the schema.history.internal properties for configuring the Debezium connector.

Table 25. Connector database schema history configuration properties
PropertyDefaultDescription

No default

The full name of the Kafka topic where the connector stores the database schema history.

No default

A list of host/port pairs that the connector uses for establishing an initial connection to the Kafka cluster. This connection is used for retrieving the database schema history previously stored by the connector, and for writing each DDL statement read from the source database. Each pair should point to the same Kafka cluster used by the Kafka Connect process.

100

An integer value that specifies the maximum number of milliseconds the connector should wait during startup/recovery while polling for persisted data. The default is 100ms.

3000

An integer value that specifies the maximum number of milliseconds the connector should wait while fetching cluster information using Kafka admin client.

30000

An integer value that specifies the maximum number of milliseconds the connector should wait while create kafka history topic using Kafka admin client.

100

The maximum number of times that the connector should try to read persisted history data before the connector recovery fails with an error. The maximum amount of time to wait after receiving no data is recovery.attempts × recovery.poll.interval.ms.

false

A Boolean value that specifies whether the connector should ignore malformed or unknown database statements or stop processing so a human can fix the issue. The safe default is false. Skipping should be used only with care as it can lead to data loss or mangling when the binlog is being processed.

false

A Boolean value that specifies whether the connector records schema structures from all tables in a schema or database, or only from tables that are designated for capture.
Specify one of the following values:

    false (default)

    During a database snapshot, the connector records the schema data for all non-system tables in the database, including tables that are not designated for capture. It’s best to retain the default setting. If you later decide to capture changes from tables that you did not originally designate for capture, the connector can easily begin to capture data from those tables, because their schema structure is already stored in the schema history topic. Debezium requires the schema history of a table so that it can identify the structure that was present at the time that a change event occurred.

    true

    During a database snapshot, the connector records the table schemas only for the tables from which Debezium captures change events. If you change the default value, and you later configure the connector to capture data from other tables in the database, the connector lacks the schema information that it requires to capture change events from the tables.

false

A Boolean value that specifies whether the connector records schema structures from all logical databases in the database instance.
Specify one of the following values:

    true

    The connector records schema structures only for tables in the logical database and schema from which Debezium captures change events.

    false

    The connector records schema structures for all logical databases.

The default value is true for MySQL Connector

Pass-through database schema history properties for configuring producer and consumer clients

Debezium relies on a Kafka producer to write schema changes to database schema history topics. Similarly, it relies on a Kafka consumer to read from database schema history topics when a connector starts. You define the configuration for the Kafka producer and consumer clients by assigning values to a set of pass-through configuration properties that begin with the schema.history.internal.producer.* and schema.history.internal.consumer.* prefixes. The pass-through producer and consumer database schema history properties control a range of behaviors, such as how these clients secure connections with the Kafka broker, as shown in the following example:

  1. schema.history.internal.producer.security.protocol=SSL
  2. schema.history.internal.producer.ssl.keystore.location=/var/private/ssl/kafka.server.keystore.jks
  3. schema.history.internal.producer.ssl.keystore.password=test1234
  4. schema.history.internal.producer.ssl.truststore.location=/var/private/ssl/kafka.server.truststore.jks
  5. schema.history.internal.producer.ssl.truststore.password=test1234
  6. schema.history.internal.producer.ssl.key.password=test1234
  7. schema.history.internal.consumer.security.protocol=SSL
  8. schema.history.internal.consumer.ssl.keystore.location=/var/private/ssl/kafka.server.keystore.jks
  9. schema.history.internal.consumer.ssl.keystore.password=test1234
  10. schema.history.internal.consumer.ssl.truststore.location=/var/private/ssl/kafka.server.truststore.jks
  11. schema.history.internal.consumer.ssl.truststore.password=test1234
  12. schema.history.internal.consumer.ssl.key.password=test1234

Debezium strips the prefix from the property name before it passes the property to the Kafka client.

See the Kafka documentation for more details about Kafka producer configuration properties and Kafka consumer configuration properties.

Debezium connector Kafka signals configuration properties

Debezium provides a set of signal.* properties that control how the connector interacts with the Kafka signals topic.

The following table describes the Kafka signal properties.

Table 26. Kafka signals configuration properties
PropertyDefaultDescription

<topic.prefix>-signal

The name of the Kafka topic that the connector monitors for ad hoc signals.

If automatic topic creation is disabled, you must manually create the required signaling topic. A signaling topic is required to preserve signal ordering. The signaling topic must have a single partition.

kafka-signal

The name of the group ID that is used by Kafka consumers.

No default

A list of host/port pairs that the connector uses for establishing an initial connection to the Kafka cluster. Each pair references the Kafka cluster that is used by the Debezium Kafka Connect process.

100

An integer value that specifies the maximum number of milliseconds that the connector waits when polling signals.

false

Enable the offset commit for the signal topic in order to guarantee At-Least-Once delivery. If disabled, only signals received when the consumer is up&running are processed. Any signals received when the consumer is down are lost.

Debezium connector pass-through signals Kafka consumer client configuration properties

The Debezium connector provides for pass-through configuration of the signals Kafka consumer. Pass-through signals properties begin with the prefix signals.consumer.*. For example, the connector passes properties such as signal.consumer.security.protocol=SSL to the Kafka consumer.

Debezium strips the prefixes from the properties before it passes the properties to the Kafka signals consumer.

Debezium connector sink notifications configuration properties

The following table describes the notification properties.

Table 27. Sink notification configuration properties
PropertyDefaultDescription

No default

The name of the topic that receives notifications from Debezium. This property is required when you configure the notification.enabled.channels property to include sink as one of the enabled notification channels.

Debezium connector pass-through database driver configuration properties

The Debezium connector provides for pass-through configuration of the database driver. Pass-through database properties begin with the prefix driver.*. For example, the connector passes properties such as driver.foobar=false to the JDBC URL.

As is the case with the pass-through properties for database schema history clients, Debezium strips the prefixes from the properties before it passes them to the database driver.

Monitoring

The Debezium MySQL connector provides three types of metrics that are in addition to the built-in support for JMX metrics that Zookeeper, Kafka, and Kafka Connect provide.

  • Snapshot metrics provide information about connector operation while performing a snapshot.

  • Streaming metrics provide information about connector operation when the connector is reading the binlog.

  • Schema history metrics provide information about the status of the connector’s schema history.

Debezium monitoring documentation provides details for how to expose these metrics by using JMX.

Snapshot metrics

The MBean is debezium.mysql:type=connector-metrics,context=snapshot,server=_<topic.prefix>_.

Snapshot metrics are not exposed unless a snapshot operation is active, or if a snapshot has occurred since the last connector start.

The following table lists the shapshot metrics that are available.

AttributesTypeDescription

string

The last snapshot event that the connector has read.

long

The number of milliseconds since the connector has read and processed the most recent event.

long

The total number of events that this connector has seen since last started or reset.

long

The number of events that have been filtered by include/exclude list filtering rules configured on the connector.

string[]

The list of tables that are captured by the connector.

int

The length the queue used to pass events between the snapshotter and the main Kafka Connect loop.

int

The free capacity of the queue used to pass events between the snapshotter and the main Kafka Connect loop.

int

The total number of tables that are being included in the snapshot.

int

The number of tables that the snapshot has yet to copy.

boolean

Whether the snapshot was started.

boolean

Whether the snapshot was paused.

boolean

Whether the snapshot was aborted.

boolean

Whether the snapshot completed.

long

The total number of seconds that the snapshot has taken so far, even if not complete. Includes also time when snapshot was paused.

long

The total number of seconds that the snapshot was paused. If the snapshot was paused several times, the paused time adds up.

Map<String, Long>

Map containing the number of rows scanned for each table in the snapshot. Tables are incrementally added to the Map during processing. Updates every 10,000 rows scanned and upon completing a table.

long

The maximum buffer of the queue in bytes. This metric is available if max.queue.size.in.bytes is set to a positive long value.

long

The current volume, in bytes, of records in the queue.

The connector also provides the following additional snapshot metrics when an incremental snapshot is executed:

AttributesTypeDescription

string

The identifier of the current snapshot chunk.

string

The lower bound of the primary key set defining the current chunk.

string

The upper bound of the primary key set defining the current chunk.

string

The lower bound of the primary key set of the currently snapshotted table.

string

The upper bound of the primary key set of the currently snapshotted table.

The Debezium MySQL connector also provides the HoldingGlobalLock custom snapshot metric. This metric is set to a Boolean value that indicates whether the connector currently holds a global or table write lock.

Streaming metrics

Transaction-related attributes are available only if binlog event buffering is enabled. See binlog.buffer.size in the advanced connector configuration properties for more details. :leveloffset: +1

The MBean is debezium.mysql:type=connector-metrics,context=streaming,server=_<topic.prefix>_.

The following table lists the streaming metrics that are available.

AttributesTypeDescription

string

The last streaming event that the connector has read.

long

The number of milliseconds since the connector has read and processed the most recent event.

long

The total number of events that this connector has seen since the last start or metrics reset.

long

The total number of create events that this connector has seen since the last start or metrics reset.

long

The total number of update events that this connector has seen since the last start or metrics reset.

long

The total number of delete events that this connector has seen since the last start or metrics reset.

long

The number of events that have been filtered by include/exclude list filtering rules configured on the connector.

string[]

The list of tables that are captured by the connector.

int

The length the queue used to pass events between the streamer and the main Kafka Connect loop.

int

The free capacity of the queue used to pass events between the streamer and the main Kafka Connect loop.

boolean

Flag that denotes whether the connector is currently connected to the database server.

long

The number of milliseconds between the last change event’s timestamp and the connector processing it. The values will incoporate any differences between the clocks on the machines where the database server and the connector are running.

long

The number of processed transactions that were committed.

Map<String, String>

The coordinates of the last received event.

string

Transaction identifier of the last processed transaction.

long

The maximum buffer of the queue in bytes. This metric is available if max.queue.size.in.bytes is set to a positive long value.

long

The current volume, in bytes, of records in the queue.

The Debezium MySQL connector also provides the following additional streaming metrics:

Table 28. Descriptions of additional streaming metrics
AttributeTypeDescription

BinlogFilename

string

The name of the binlog file that the connector has most recently read.

BinlogPosition

long

The most recent position (in bytes) within the binlog that the connector has read.

IsGtidModeEnabled

boolean

Flag that denotes whether the connector is currently tracking GTIDs from MySQL server.

GtidSet

string

The string representation of the most recent GTID set processed by the connector when reading the binlog.

NumberOfSkippedEvents

long

The number of events that have been skipped by the MySQL connector. Typically events are skipped due to a malformed or unparseable event from MySQL’s binlog.

NumberOfDisconnects

long

The number of disconnects by the MySQL connector.

NumberOfRolledBackTransactions

long

The number of processed transactions that were rolled back and not streamed.

NumberOfNotWellFormedTransactions

long

The number of transactions that have not conformed to the expected protocol of BEGIN + COMMIT/ROLLBACK. This value should be 0 under normal conditions.

NumberOfLargeTransactions

long

The number of transactions that have not fit into the look-ahead buffer. For optimal performance, this value should be significantly smaller than NumberOfCommittedTransactions and NumberOfRolledBackTransactions.

Schema history metrics

The MBean is debezium.mysql:type=connector-metrics,context=schema-history,server=_<topic.prefix>_.

The following table lists the schema history metrics that are available.

AttributesTypeDescription

string

One of STOPPED, RECOVERING (recovering history from the storage), RUNNING describing the state of the database schema history.

long

The time in epoch seconds at what recovery has started.

long

The number of changes that were read during recovery phase.

long

the total number of schema changes applied during recovery and runtime.

long

The number of milliseconds that elapsed since the last change was recovered from the history store.

long

The number of milliseconds that elapsed since the last change was applied.

string

The string representation of the last change recovered from the history store.

string

The string representation of the last applied change.

Behavior when things go wrong

Debezium is a distributed system that captures all changes in multiple upstream databases; it never misses or loses an event. When the system is operating normally or being managed carefully then Debezium provides exactly once delivery of every change event record.

If a fault does happen then the system does not lose any events. However, while it is recovering from the fault, it might repeat some change events. In these abnormal situations, Debezium, like Kafka, provides at least once delivery of change events.

The rest of this section describes how Debezium handles various kinds of faults and problems.

Configuration and startup errors

In the following situations, the connector fails when trying to start, reports an error or exception in the log, and stops running:

  • The connector’s configuration is invalid.

  • The connector cannot successfully connect to the MySQL server by using the specified connection parameters.

  • The connector is attempting to restart at a position in the binlog for which MySQL no longer has the history available.

In these cases, the error message has details about the problem and possibly a suggested workaround. After you correct the configuration or address the MySQL problem, restart the connector.

MySQL becomes unavailable

If your MySQL server becomes unavailable, the Debezium MySQL connector fails with an error and the connector stops. When the server is available again, restart the connector.

However, if GTIDs are enabled for a highly available MySQL cluster, you can restart the connector immediately. It will connect to a different MySQL server in the cluster, find the location in the server’s binlog that represents the last transaction, and begin reading the new server’s binlog from that specific location.

If GTIDs are not enabled, the connector records the binlog position of only the MySQL server to which it was connected. To restart from the correct binlog position, you must reconnect to that specific server.

Kafka Connect stops gracefully

When Kafka Connect stops gracefully, there is a short delay while the Debezium MySQL connector tasks are stopped and restarted on new Kafka Connect processes.

Kafka Connect process crashes

If Kafka Connect crashes, the process stops and any Debezium MySQL connector tasks terminate without their most recently-processed offsets being recorded. In distributed mode, Kafka Connect restarts the connector tasks on other processes. However, the MySQL connector resumes from the last offset recorded by the earlier processes. This means that the replacement tasks might generate some of the same events processed prior to the crash, creating duplicate events.

Each change event message includes source-specific information that you can use to identify duplicate events, for example:

  • Event origin

  • MySQL server’s event time

  • The binlog file name and position

  • GTIDs (if used)

Kafka becomes unavailable

The Kafka Connect framework records Debezium change events in Kafka by using the Kafka producer API. If the Kafka brokers become unavailable, the Debezium MySQL connector pauses until the connection is reestablished and the connector resumes where it left off.

MySQL purges binlog files

If the Debezium MySQL connector stops for too long, the MySQL server purges older binlog files and the connector’s last position may be lost. When the connector is restarted, the MySQL server no longer has the starting point and the connector performs another initial snapshot. If the snapshot is disabled, the connector fails with an error.

See snapshots for details about how MySQL connectors perform initial snapshots.