Metric Reporters
Flink allows reporting metrics to external systems. For more information about Flink’s metric system go to the metric system documentation.
Reporter
Metrics can be exposed to an external system by configuring one or several reporters in conf/flink-conf.yaml
. These reporters will be instantiated on each job and task manager when they are started.
metrics.reporter.<name>.<config>
: Generic setting<config>
for the reporter named<name>
.metrics.reporter.<name>.class
: The reporter class to use for the reporter named<name>
.metrics.reporter.<name>.factory.class
: The reporter factory class to use for the reporter named<name>
.metrics.reporter.<name>.interval
: The reporter interval to use for the reporter named<name>
.metrics.reporter.<name>.scope.delimiter
: The delimiter to use for the identifier (default value usemetrics.scope.delimiter
) for the reporter named<name>
.metrics.reporter.<name>.scope.variables.excludes
: (optional) A semi-colon (;) separate list of variables that should be ignored by tag-based reporters (e.g., Prometheus, InfluxDB).metrics.reporters
: (optional) A comma-separated include list of reporter names. By default all configured reporters will be used.
All reporters must at least have either the class
or factory.class
property. Which property may/should be used depends on the reporter implementation. See the individual reporter configuration sections for more information. Some reporters (referred to as Scheduled
) allow specifying a reporting interval
. Below more settings specific to each reporter will be listed.
Example reporter configuration that specifies multiple reporters:
metrics.reporters: my_jmx_reporter,my_other_reporter
metrics.reporter.my_jmx_reporter.factory.class: org.apache.flink.metrics.jmx.JMXReporterFactory
metrics.reporter.my_jmx_reporter.port: 9020-9040
metrics.reporter.my_jmx_reporter.scope.variables.excludes:job_id;task_attempt_num
metrics.reporter.my_other_reporter.class: org.apache.flink.metrics.graphite.GraphiteReporter
metrics.reporter.my_other_reporter.host: 192.168.1.1
metrics.reporter.my_other_reporter.port: 10000
Important: The jar containing the reporter must be accessible when Flink is started. Reporters that support the factory.class
property can be loaded as plugins. Otherwise the jar must be placed in the /lib folder. Reporters that are shipped with Flink (i.e., all reporters documented on this page) are available by default.
You can write your own Reporter
by implementing the org.apache.flink.metrics.reporter.MetricReporter
interface. If the Reporter should send out reports regularly you have to implement the Scheduled
interface as well. By additionally implementing a MetricReporterFactory
your reporter can also be loaded as a plugin.
The following sections list the supported reporters.
JMX
(org.apache.flink.metrics.jmx.JMXReporter)
You don’t have to include an additional dependency since the JMX reporter is available by default but not activated.
Parameters:
port
- (optional) the port on which JMX listens for connections. In order to be able to run several instances of the reporter on one host (e.g. when one TaskManager is colocated with the JobManager) it is advisable to use a port range like9250-9260
. When a range is specified the actual port is shown in the relevant job or task manager log. If this setting is set Flink will start an extra JMX connector for the given port/range. Metrics are always available on the default local JMX interface.
Example configuration:
metrics.reporter.jmx.factory.class: org.apache.flink.metrics.jmx.JMXReporterFactory
metrics.reporter.jmx.port: 8789
Metrics exposed through JMX are identified by a domain and a list of key-properties, which together form the object name.
The domain always begins with org.apache.flink
followed by a generalized metric identifier. In contrast to the usual identifier it is not affected by scope-formats, does not contain any variables and is constant across jobs. An example for such a domain would be org.apache.flink.job.task.numBytesOut
.
The key-property list contains the values for all variables, regardless of configured scope formats, that are associated with a given metric. An example for such a list would be host=localhost,job_name=MyJob,task_name=MyTask
.
The domain thus identifies a metric class, while the key-property list identifies one (or multiple) instances of that metric.
Graphite
(org.apache.flink.metrics.graphite.GraphiteReporter)
Parameters:
host
- the Graphite server hostport
- the Graphite server portprotocol
- protocol to use (TCP/UDP)
Example configuration:
metrics.reporter.grph.factory.class: org.apache.flink.metrics.graphite.GraphiteReporterFactory
metrics.reporter.grph.host: localhost
metrics.reporter.grph.port: 2003
metrics.reporter.grph.protocol: TCP
metrics.reporter.grph.interval: 60 SECONDS
InfluxDB
(org.apache.flink.metrics.influxdb.InfluxdbReporter)
In order to use this reporter you must copy /opt/flink-metrics-influxdb-1.13.0.jar
into the plugins/influxdb
folder of your Flink distribution.
Parameters:
Key | Default | Type | Description |
---|---|---|---|
connectTimeout | 10000 | Integer | (optional) the InfluxDB connect timeout for metrics |
consistency | ONE | Enum Possible values: [ALL, ANY, ONE, QUORUM] | (optional) the InfluxDB consistency level for metrics |
db | (none) | String | the InfluxDB database to store metrics |
host | (none) | String | the InfluxDB server host |
password | (none) | String | (optional) InfluxDB username’s password used for authentication |
port | 8086 | Integer | the InfluxDB server port |
retentionPolicy | (none) | String | (optional) the InfluxDB retention policy for metrics |
scheme | http | Enum Possible values: [http, https] | the InfluxDB schema |
username | (none) | String | (optional) InfluxDB username used for authentication |
writeTimeout | 10000 | Integer | (optional) the InfluxDB write timeout for metrics |
Example configuration:
metrics.reporter.influxdb.factory.class: org.apache.flink.metrics.influxdb.InfluxdbReporterFactory
metrics.reporter.influxdb.scheme: http
metrics.reporter.influxdb.host: localhost
metrics.reporter.influxdb.port: 8086
metrics.reporter.influxdb.db: flink
metrics.reporter.influxdb.username: flink-metrics
metrics.reporter.influxdb.password: qwerty
metrics.reporter.influxdb.retentionPolicy: one_hour
metrics.reporter.influxdb.consistency: ANY
metrics.reporter.influxdb.connectTimeout: 60000
metrics.reporter.influxdb.writeTimeout: 60000
metrics.reporter.influxdb.interval: 60 SECONDS
The reporter would send metrics using http protocol to the InfluxDB server with the specified retention policy (or the default policy specified on the server). All Flink metrics variables (see List of all Variables) are exported as InfluxDB tags.
Prometheus
(org.apache.flink.metrics.prometheus.PrometheusReporter)
Parameters:
port
- (optional) the port the Prometheus exporter listens on, defaults to 9249. In order to be able to run several instances of the reporter on one host (e.g. when one TaskManager is colocated with the JobManager) it is advisable to use a port range like9250-9260
.filterLabelValueCharacters
- (optional) Specifies whether to filter label value characters. If enabled, all characters not matching [a-zA-Z0-9:_] will be removed, otherwise no characters will be removed. Before disabling this option please ensure that your label values meet the Prometheus requirements.
Example configuration:
metrics.reporter.prom.class: org.apache.flink.metrics.prometheus.PrometheusReporter
Flink metric types are mapped to Prometheus metric types as follows:
Flink | Prometheus | Note |
---|---|---|
Counter | Gauge | Prometheus counters cannot be decremented. |
Gauge | Gauge | Only numbers and booleans are supported. |
Histogram | Summary | Quantiles .5, .75, .95, .98, .99 and .999 |
Meter | Gauge | The gauge exports the meter’s rate. |
All Flink metrics variables (see List of all Variables) are exported to Prometheus as labels.
PrometheusPushGateway
(org.apache.flink.metrics.prometheus.PrometheusPushGatewayReporter)
Parameters:
Key | Default | Type | Description |
---|---|---|---|
deleteOnShutdown | true | Boolean | Specifies whether to delete metrics from the PushGateway on shutdown. |
filterLabelValueCharacters | true | Boolean | Specifies whether to filter label value characters. If enabled, all characters not matching [a-zA-Z0-9:_] will be removed, otherwise no characters will be removed. Before disabling this option please ensure that your label values meet the Prometheus requirements. |
groupingKey | (none) | String | Specifies the grouping key which is the group and global labels of all metrics. The label name and value are separated by ‘=’, and labels are separated by ‘;’, e.g., k1=v1;k2=v2 . Please ensure that your grouping key meets the Prometheus requirements. |
host | (none) | String | The PushGateway server host. |
jobName | (none) | String | The job name under which metrics will be pushed |
port | -1 | Integer | The PushGateway server port. |
randomJobNameSuffix | true | Boolean | Specifies whether a random suffix should be appended to the job name. |
Example configuration:
metrics.reporter.promgateway.class: org.apache.flink.metrics.prometheus.PrometheusPushGatewayReporter
metrics.reporter.promgateway.host: localhost
metrics.reporter.promgateway.port: 9091
metrics.reporter.promgateway.jobName: myJob
metrics.reporter.promgateway.randomJobNameSuffix: true
metrics.reporter.promgateway.deleteOnShutdown: false
metrics.reporter.promgateway.groupingKey: k1=v1;k2=v2
metrics.reporter.promgateway.interval: 60 SECONDS
The PrometheusPushGatewayReporter pushes metrics to a Pushgateway, which can be scraped by Prometheus.
Please see the Prometheus documentation for use-cases.
StatsD
(org.apache.flink.metrics.statsd.StatsDReporter)
Parameters:
host
- the StatsD server hostport
- the StatsD server port
Example configuration:
metrics.reporter.stsd.factory.class: org.apache.flink.metrics.statsd.StatsDReporterFactory
metrics.reporter.stsd.host: localhost
metrics.reporter.stsd.port: 8125
metrics.reporter.stsd.interval: 60 SECONDS
Datadog
(org.apache.flink.metrics.datadog.DatadogHttpReporter)
Note any variables in Flink metrics, such as <host>
, <job_name>
, <tm_id>
, <subtask_index>
, <task_name>
, and <operator_name>
, will be sent to Datadog as tags. Tags will look like host:localhost
and job_name:myjobname
.
Note Histograms are exposed as a series of gauges following the naming convention of Datadog histograms (<metric_name>.<aggregation>
). The min
aggregation is reported by default, whereas sum
is not available. In contrast to Datadog-provided Histograms the reported aggregations are not computed for a specific reporting interval.
Parameters:
apikey
- the Datadog API keytags
- (optional) the global tags that will be applied to metrics when sending to Datadog. Tags should be separated by comma onlyproxyHost
- (optional) The proxy host to use when sending to Datadog.proxyPort
- (optional) The proxy port to use when sending to Datadog, defaults to 8080.dataCenter
- (optional) The data center (EU
/US
) to connect to, defaults toUS
.maxMetricsPerRequest
- (optional) The maximum number of metrics to include in each request, defaults to 2000.
Example configuration:
metrics.reporter.dghttp.factory.class: org.apache.flink.metrics.datadog.DatadogHttpReporterFactory
metrics.reporter.dghttp.apikey: xxx
metrics.reporter.dghttp.tags: myflinkapp,prod
metrics.reporter.dghttp.proxyHost: my.web.proxy.com
metrics.reporter.dghttp.proxyPort: 8080
metrics.reporter.dghttp.dataCenter: US
metrics.reporter.dghttp.maxMetricsPerRequest: 2000
metrics.reporter.dghttp.interval: 60 SECONDS
Slf4j
(org.apache.flink.metrics.slf4j.Slf4jReporter)
Example configuration:
metrics.reporter.slf4j.factory.class: org.apache.flink.metrics.slf4j.Slf4jReporterFactory